Important Isocyanate (ISO) Information
6
311320K
Important Isocyanate (ISO) Information
Isocyanates (ISO) are catalysts used in two component materials.
Isocyanate Conditions
Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized
particulates.
•
Read and understand the fluid manufacturer’s warnings and
Safety Data Sheets (SDSs) to know specific
hazards and precautions related to isocyanates.
•
Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment unless you
are trained, qualified, and have read and understood the information in this manual and in the fluid
manufacturer’s application instructions and SDSs.
•
Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material, which could
cause off gassing and offensive odors. Equipment must be carefully maintained and adjusted according to
instructions in the manual.
•
To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work area must
wear appropriate respiratory protection. Always wear a properly fitting respirator, which may include a
supplied-air respirator. Ventilate the work area according to instructions in the fluid manufacturer’s SDSs.
•
Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable
gloves, protective clothing and foot coverings as recommended by the fluid manufacturer and local regulatory
authority. Follow all fluid manufacturer recommendations, including those regarding handling of
contaminated clothing. After spraying, wash hands and face before eating or drinking.
•
Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal
protective equipment must stay out of the work area during application and after application for the time
period specified by the fluid manufacturer. Generally this time period is at least 24 hours.
•
Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommendations
of the fluid manufacturer and local regulatory authority. Posting a placard such as the following outside the
work area is recommended:
TOXIC FUMES
HAZARD
DO NOT ENTER
DURING
SPRAY FOAM APPLICATION
OR FOR ___ HOURS AFTER
APPLICATION IS COMPLETE
DO NOT ENTER UNTIL:
DATE:
TIME:
____________
____________