16
307132
Operation
Proportioning Pump Chart
Displacement pump combinations for mix ratio, pres-
sure ratio and volume per cycle for each model.
CAUTION
With three displacement pump models, the outer two
displacement pumps must be identical models to
balance forces and avoid damaging the pumps.
Mix
Part A
Part B
Part A
Pressure
Ratio
(fluid to air)
Volume per
Cycle
Gallon (liter)
Fluid Pressure Developed
psi (MPa, bar)
at incoming air pressure of
psi (MPa, bar)
1:1
222012
222012
None
34:1*
0.046 (0.17)
2500 (17, 170)
74 (0.5, 5.2)
1-1/4:1 222019
222015
222019
38:1*
0.034 (0.13)
2500 (17, 170)
66 (0.4, 4.5)
1-1/2:1 222019
222017
222019
41:1*
0.038 (0.14)
2500 (17, 170)
61 (0.4, 4.2)
2:1
222012
222012
222012
23:1
0.068 (0.26)
2300 (16, 161)
100 (0.7, 7)
2-1/2:1 222012
222015
222012
24:1
0.064 (0.24)
2400 (16.8, 168)
100 (0.7, 7)
3:1
222012
222017
222012
25:1
0.061 (0.23)
2500 (17, 170)
100 (0.7, 7)
4:1
222012
222019
222012
27:1
0.057 (0.22)
2500 (17, 170)
93 (0.6, 6.4)
* Exceeds the pressure ratiing of the pumps.
Relief Valve Selection Table
To select the appropriate relief valve:
1.
Determine the Maximum Pump Fluid Pressure of
your system.
2.
Verify that all system components meet or exceed
the pressure ratings of the pressure relief valve
that you have selected.
3.
Select the lowest pressure relief valve with a maxi-
mum working pressure that exceeds the Maximum
Pump Fluid Pressure.
Part
Number
Working Pressure
Range psi (MPa, bar)
Cracking Pressure
Range psi (MPa, bar)
Minimum
Maximum
Minimum
Maximum
237060
475
(3.3, 33)
575
(4, 40)
710
(4.9, 49)
860
(5.9, 59)
237061
950
(6.6, 66)
1150
(7.9, 79)
1425
(9.8, 98)
1725
(11.9,
119)
237112
1400
(9.7, 97)
1800
(12.4,
124)
2140
(14.8,
148)
2590
(17.9,
179)
237062
1800
(12.4,
124)
2300
(15.9,
159)
2850
(19.7,
197)
3450
(23.8,
238)
Содержание BULLDOG HYDRA-CAT 208958
Страница 17: ...307132 17 Notes...