307132
5
Installation
These pumps are designed to be part of a Hydra-Cat
spray system that will proportion, mix, and spray/dispense
two-component fluids. The following two typical installations are only guidelines to setting up a complete Hydra-
Cat
system. For assistance in designing a system to suit your particular needs, contact your Graco distributor.
05225
For pressure feed to proportioning pump, mount
fluid pressure gauges at proportioning pump inlets
to properly adjust feed pump pressures.
1
1
D A
C
N
E
A
B
A
D
A
M
F
P
F
J
G
G
C B
H
PART A
PART B
LIGHT VISCOSITY SYSTEM
5:1 RATIO MAXIMUM RATIO FEED PUMPS
KEY
A
Bleed-type master
air valve
B
Pump runaway valve
C
Air line lubricator
D
Air regulator
E
Air line filter
F
Fluid filter
G
Fluid drain valve
H
Feed pump
J
Proportioning pump
K
Solvent pump
L
Flushing valve
M
Static mixer
N
Spray valve
P
Ground wire
A
A
A
C B
G
L
PART A
PART B
K
D
C
H
G
G
D A
B
Содержание BULLDOG HYDRA-CAT 208958
Страница 17: ...307132 17 Notes...
Страница 23: ...307132 23 Notes...