Warnings
4
3A4442B
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent
and paint fumes, in work area can ignite or
explode. To help prevent fire and explosion:
•
Do not spray or clean with flammable materials. Use water-based materials only.
•
Use equipment only in well ventilated area.
•
Sprayer generates sparks. When flammable liquids are used near the sprayer,
keep sprayer at least 20 feet (6.1 meters) away from explosive vapors.
•
Eliminate all ignition sources.
•
Keep work area free of debris, including solvent, rags and gasoline.
•
Ground all equipment in the work area. See
Grounding
instructions.
•
Keep a working fire extinguisher in the work area.
SKIN INJECTION HAZARD
High-pressure spray is able to inject toxins into the body and cause serious bodily
injury. In the event that injection occurs,
get immediate surgical treatment.
•
Do not aim the gun at, or spray any person or animal.
•
Keep hands and other body parts away from the discharge. For example, do not
try to stop leaks with any part of the body.
•
Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
•
Use Graco nozzle tips.
•
Use caution when cleaning and changing nozzle tips. In the case where the
nozzle tip clogs while spraying, follow the
Pressure Relief Procedure
for turning
off the unit and relieving the pressure before removing the nozzle tip to clean.
•
Equipment maintains pressure after power is shut off. Do not leave the
equipment energized or under pressure while unattended. Follow the
Pressure
Relief Procedure
when the equipment is unattended or not in use, and before
servicing, cleaning, or removing parts.
•
Check hoses and parts for signs of damage. Replace any damaged hoses or
parts.
•
This system is capable of producing 3000 psi (207 bar, 20.7 MPa). Use Graco
replacement parts or accessories that are rated a minimum of 3000 psi (207 bar,
20.7 MPa).
•
Always engage the trigger lock when not spraying. Verify the trigger lock is
functioning properly.
•
Verify that all connections are secure before operating the unit.
•
Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with
the controls.
Содержание 3A4442B
Страница 47: ...Notes 3A4442B 47 Notes ...