Troubleshooting
32
3A4442B
Sprayer does not run at all
Display shows CODE 06
Allow sprayer to cool. If sprayer
runs when cool, correct cause of
overheating. Keep sprayer in
cooler location with good
ventilation. Make sure motor air
intake is not blocked. If sprayer still
does not run, follow Step 1.
NOTE:
Motor must be cooled
down for the test.
1.Check thermal device connector
(yellow wires) at control board.
2.Disconnect thermal device
connector from control board
socket. Make sure contacts are
clean and secure. Measure
resistance of the thermal device. If
reading is not correct, replace
motor.
Check Motor Thermal Switch:
Unplug thermal wires. Set meter to
ohms. Meter should read the proper
resistance for each unit (see table
below).
Reconnect thermal device
connector to control board socket.
Connect power, turn sprayer ON
and control knob 1/2 turn clockwise.
If sprayer does not run, replace
control board.
Sprayer does not run at all
Display shows CODE 08
Check voltage supply to the
sprayer (incoming voltage too low
for sprayer operation)
1.Set sprayer to OFF and disconnect
power to sprayer.
2.Remove other equipment that uses
the same circuit.
3.Locate a good voltage supply to
avoid damage to electronics.
Problem
What to Check
How to check
-
ti13140a
Resistance Table:
APX 6200
6.2k ohms
APX 8200
10.0k
ohms