309180
9
Mechanical Setup
4.
Fill wet cup (Fig. 4), located on top of the displace-
ment pump, 2/3 full of Graco TSL. fluid.
Fig. 4
PH00013
5.
Back–off all air regulators (Fig. 5 and Fig. 6) to
their full counterclockwise position.
NOTE:
The UP/DOWN control lever is shipped inside
the ram control box and should be screwed onto the
face of the control now.
Fig. 5
PH00014
6.
Connect a 1/2” air line from an air source, capable
of delivering a minimum of 15 cfm (0.4 m
3
/m) at 80
psi (552 kPa, 5.5 bar), to the air control (Fig. 6).
DO NOT USE QUICK DISCONNECTS
.
PH00032
Fig. 6