Operation
3A4802D
21
Winterizing the Equipment
1.
Drain the pot (see Draining the Pot page 18).
2.
Close the air supply valve (Q).
3.
Disconnect the water supply.
4.
Remove the pump inlet hose from the pump inlet
and drain.
NOTE: All disposals must comply with national,
state, and local regulations.
5.
Connect the included siphon hose to the pump, then
insert the end into a windshield wash container.
Choose a windshield wash with a rating that will pro-
tect the equipment for the lowest temperature in
your area.
6.
Open the air supply valve.
7.
Turn the selector valve to BLAST with the abrasive
metering valve 1/4 turn open until the blast water
tubing is full of windshield wash.
8.
Turn the selector valve to WASH. Confirm that the
wash tubing fills with windshield wash.
9.
Close the air supply valve.
10. Remove fill/flush line from the water supply manifold
and drain water. Reconnect the fill/flush line.
11. Open all ball valves and the abrasive metering
valve.
12. Reconnect the pump inlet hose.
NOTICE
Vapor abrasive blasters must be winterized whenever
there is a possibility of freezing temperatures during stor-
age to avoid damage to the equipment.
WLD
WLD
NOTICE
When ice forms behind the seals, the seals can become
damaged. During storage, position all ball valves in the
open position.
ti30729a
WLD
Содержание 278860
Страница 31: ...Notes 3A4802D 31 Notes ...
Страница 35: ...Parts 3A4802D 35 Enclosure Parts WL D 1 Apply anti sieze to threads ...
Страница 37: ...Parts 3A4802D 37 Enclosure Parts continued WL D ...
Страница 43: ...Dimensions 3A4802D 43 Dimensions WL D PP PP PP ...
Страница 44: ...Notes 44 3A4802D Notes ...