Installation
4
3A5278B
Installation
The Communications Gateway Module must be
installed in the XM system. The XM system does not
provide a mounting position for this module. It will need
a cable connection to the display module and can be
mounted either close by or at a distance of up to 50 ft
(50 m).
After installing the CGM as desired, connect the CAN
cable adapter (3) to the open connection on the display
module. Connect the CAN cable (2) to the adapter.
Connect the other end of the CAN cable to either of the
two connectors on the CGM. Alternate lengths of the
CAN cable are available and listed in
Install Upgrade Tokens
NOTE:
The XM system requires updated software to
use the CGM. See
, page 22, for details.
To install software upgrades:
1. Use software token (4). See the Graco Control
Architecture
™
(GCA) Module Programming manual
for instructions.
NOTE:
Upgrade all modules in the system to the
software version on the token. Different software
versions may not be compatible.
All data in the module (system settings, USB logs
maintenance counters) may be reset to factory default
settings. Download all settings and user preferences to
a USB before the upgrade, for ease of restoring them
following the upgrade.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
WARNING
ELECTRIC SHOCK HAZARD
To prevent electric shock:
•
Turn off and disconnect power at XM
system main switch before installing
the Communications Gateway Module,
disconnecting any cables, or servicing
equipment.
•
All electrical wiring must be done by a
qualified electrician and comply with all
local codes and regulations.