background image

Setup 

12

3A5278B

Screens

See XM Operations manual (MM 312359) for details of system operation. The following shows the XM display and 
the gateway signal information available for each screen.

Run (Fluid Control)

Pump On/Enter Mode

Spray Mode

Shown with pump turned on.

F

IG

. 15: Pump On/Enter Mode

F

IG

. 16: Spray Mode

3

4

5

2

1

6

3

4

5

2

1

6

8

Содержание 26A530

Страница 1: ...ns abilities For professional use only Not approved for use in explosive atmospheres or hazardous locations See page 2 for part and XM model information Important Safety Instructions Read all warnings...

Страница 2: ...ations Gateway Module can be used with the following XM models These are not for use in explosive atmospheres or hazardous locations See the XM Operation manual MM 312359 for details of these models X...

Страница 3: ...between the XM system and a selected fieldbus This provides the means for remote monitoring and control by external automation systems See CGM I O Data Map page 11 for a list of internal data from the...

Страница 4: ...To install software upgrades 1 Use software token 4 See the Graco Control Architecture GCA Module Programming manual for instructions NOTE Upgrade all modules in the system to the software version on...

Страница 5: ...press map token 5 firmly into slot 4 Press and hold the map upload push button B for three seconds The red LED C will flash twice pause and repeat once after the data map is successfully uploaded This...

Страница 6: ...go to fieldbus screens NOTE The fieldbus screen will not display if CAN cables are not connected Ensure that all CGM CAN cables are connected PROFIBUS Fieldbus Screens Screen 1 This screen enables you...

Страница 7: ...P address station name and installation date FIG 4 PROFIBUS Fieldbus Screen 2 Parameter Range Location Tag 22 characters available Function Tag 32 characters available Description 54 characters availa...

Страница 8: ...fication information for the Datamap that has been loaded into the CGM FIG 7 PROFINET Fieldbus Screen 2 Parameter Range DHCP Yes or No Subnet Mask Set as required Gateway Set as required DNS1 Set as r...

Страница 9: ...serial number device address and baud rate Screen 2 This screen lists identification information for the Datamap that has been loaded into the CGM FIG 10 DeviceNet Fieldbus Screen 1 Parameter Range H...

Страница 10: ...1 and DNS 2 Screen 3 This screen lists identification information for the Datamap that has been loaded into the CGM FIG 12 EtherNet IP Fieldbus Screen 1 Parameter Range Hardware Revision System Serial...

Страница 11: ...nt Code Integer BYTES 8 11 Temperature A Integer BYTES 12 13 Temperature B Integer BYTES 14 15 Pressure A Integer BYTES 16 17 Pressure B Integer BYTES 18 19 Flow Rate A Integer BYTES 20 21 Flow Rate B...

Страница 12: ...tails of system operation The following shows the XM display and the gateway signal information available for each screen Run Fluid Control Pump On Enter Mode Spray Mode Shown with pump turned on FIG...

Страница 13: ...n NOTE All versions of this screen display the sum of Flow Rate A and Flow Rate B Some operation modes display A and B separately The gateways always provide Flow Rate A and Flow Rate B independently...

Страница 14: ...p Test 6 Ratio Test Batch Dispense 8 Inactive system off 9 Valve Test All other values are unused Operation Mode Control Acceptable values are 0 1 2 3 4 or 8 All other values will be rejected 5 Pressu...

Страница 15: ...arms 2 Voltage Sys tem DC mV Read Only FIG 20 Totalizers and Job Number Screen Label Input to PLC Description Units Comments Output from PLC Description 1 Batch Total A Batch Total B Liters gal lons U...

Страница 16: ...et Ratio Integer Ratio in thousandths That is 1200 1 2 1 ratio 1800 1 8 1 ratio Volume Ratio Target Ctrl FIG 22 Date Time Units Screen Label Input to PLC Description Units Comments Output from PLC Des...

Страница 17: ...ased on value of System in Weight Mode Ratio is in thousandths That is 1200 1 2 1 ratio 1800 1 8 1 ratio Event Code Contains the 4 character event code as ASCII characters but only the most recent to...

Страница 18: ...weight depending on current system mode The particular volume or weight units depend on the setting of units in the display The value will be in tenths of gallons liters pounds or kilograms That is I...

Страница 19: ...rom 1 to 60 seconds Job Number The current job number of the system Voltage System DC DC supply voltage in the system in mV Values Units 0 F 1 C Values Units Display Flow Rate Settings 0 liter cc min...

Страница 20: ...ill be rejected Volume Ratio Target Ctrl The target volume ratio can only be set when the system is in volume mode See System in Weight Mode page 18 Ratio in thousandths That is 1200 1 2 1 ratio 1800...

Страница 21: ...ent job number Job numbers from 0 to 9999 are valid All other values will be ignored Values Units 0 Reset batch totalizers 1 Must set to 0 before setting to 1 to reset batch totalizers again Values Un...

Страница 22: ...alternate length cables are also available separately WL D Ref Part Description Qty 1 MODULE Communications Gateway 1 CGMDN0 DeviceNet 26A530 only CGMEP0 EtherNet IP 26A531 only CGMPB0 PROFIBUS 26A532...

Страница 23: ...Parts 3A5278B 23...

Страница 24: ...terial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIE...

Отзывы: