Setup
14
3A5278B
3
Pump On Off
Integer
0 = Pump is off
1 = Pump is on
Highlighted icon indicates pump is
on.
Pump On Off Control
4
Operation
Mode
Integer
Icon on display indicates operation
mode.
0 = Spray
1 = Run Pump A (recirc)
2 = Run Pump B (recirc)
3 = Run Pump AB (recirc)
4 = Park
5 = Pump Test
6 = Ratio Test/Batch Dispense
8 = Inactive (system off)
9 = Valve Test
All other values are unused
Operation Mode Control
Acceptable values are 0, 1, 2, 3, 4,
or 8
All other values will be rejected
5
Pressure A
Pressure B
psi, bar,
MPa
Read Only
6
Temperature A
Temperature B
°F or °C
Read Only
7
Flow Rate A
Flow Rate B
cc/min
Read Only
8
Actual Ratio
Ratio is in thousandths
1200 is 1.2:1 ratio
Read Only
Label
Input to PLC
Description
Units
Comments
Output from PLC Description