Repair
24
3A8570B
Reassembly
1. Place the relief ball (7) i into position in the pump
housing (see F
2. Replace the spring guide (8) (see F
. 34).
3. Replace the spring (9) (F
4. Tighten the relief valve housing into the pump
housing (F
NOTE: Do not loosen the cap nut and nut since this will
change the pressure setting.).
5. Complete using the
information
beginning on page 9.
Pump Outlet Check Valve
Replacement with Thermal
Relief P/N 133097
Disassembly
. page 10.
2. Turn off and disconnect the power to the pump.
3. Remove the standard check valve (17) from the
outlet fitting (18) (F
Reassembly
1. Tighten the outlet check valve with built-in thermal
relief (Torque 30 ft-lbs, 40.7 N•m).
beginning on page 9.
F
IG
. 35
17
18
Содержание 25T817