background image

Operation 

6

334852D

NOTE: 

To interrupt or restart the calibration dispense at any 
time during the dispense, push the TOTAL button. 
This will reset the display back to 00.00 to start over. 

If RESET is pressed before the calibration factor is 
calculated, the meter will disregard the new calibra-
tion information and exit the Setup Mode.

Restoring the Default Calibration Factor

From the CAL screen:

1.

Start a dispense to register a count.

2.

Quickly press and release the TOTAL button to reset 
the calibration dispense to 00.00.

NOTE:

 The UOM; either QTS or L, will flash on the 

display. 

3.

Press and hold TOTAL until 1.00 displays on the 
screen and the UOM stops flashing.

4.

Press the RESET button to save the default calibra-
tion factor and exit the Setup Mode.

To Verify the Accuracy of an 
Electronic Meter

1.

Use a clean, calibrated container. If using a single 
container, be sure to clean it after each dispense.

2.

Have pump air pressure at the lowest possible set-
ting for dispensing fluid.

3.

Put the tip of the nozzle at the bottom of the cali-
brated container.

4.

If the tip of the dispense valve does not reach the 
bottom of the calibrated container, use a length of 
plastic tubing over the tip of the nozzle to ensure liq-
uid enters the container from the bottom.

5.

Trigger the gun slowly so the fluid immediately cov-
ers the tip of the dispense valve.

6.

Allow product to sit for 20 minutes, then compare 
the actual, physical measurement in the calibrated 
container to the measure displayed on the meter.

NOTE: 

The procedure above will determine if the meter 

is accurately dispensing the product and minimize test-
ing errors. Some variance may occur depending on the 
viscosity of the fluid. If this procedure determines that 
the meter is not accurate recalibrate the meter using the 
procedure outlined in the Calibration Mode instructions, 
page 5.

For Maximum Dispensing 
Accuracy

(gallon/quart/pint dispenses only)

Set the meter to dispense in pints or quarts when dis-
pensing 1 gallon or less.

Always press the 

RESET

 key pad to clear the meter 

before a new dispense cycle.

F

IG

. 7

Содержание 24V553

Страница 1: ...heres or hazardous locations For professional use only Models 24V553 Measures in gallons quarts pints and liters Meter is factory set in quarts Calibrate after electronic module replacement 1500 psi 10 3 MPa 103 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ...

Страница 2: ...ace worn or damaged parts immediately with genuine manufac turer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables...

Страница 3: ...d installing an in line meter It is not an actual system design Contact your Graco representative for assistance in designing a system to suit your needs Key A In line meter B In line strainer C Shutoff valve D Pressure relief valve E Check valve F Bleed off valve drain valve G Bleed type master air valve FIG 1 A B C D E F G ...

Страница 4: ...y running fluid through the meter FIG 2 NOTE The digital display on the meter goes blank after approximately two minutes of non use Function of TOTAL To see the accumulated total of fluid dispensed through the meter press the TOTAL key The meter can accu mulate a running total of up to 19 999 units dispensed before returning to zero FIG 3 Function of RESET Press the RESET key to clear the quantity...

Страница 5: ... instructions in the following section of this manual Calibration Mode The meter has a preset calibration factor from the factory From the CAL screen NOTE Instructions for displaying the CAL screen are provided in Setup Mode steps 1 5 1 To save the current Calibration factor press RESET and the unit will save and exit setup 2 To recalibrate the meter a Dispense 1 Quart or 1 Liter of fluid into a c...

Страница 6: ...the lowest possible set ting for dispensing fluid 3 Put the tip of the nozzle at the bottom of the cali brated container 4 If the tip of the dispense valve does not reach the bottom of the calibrated container use a length of plastic tubing over the tip of the nozzle to ensure liq uid enters the container from the bottom 5 Trigger the gun slowly so the fluid immediately cov ers the tip of the disp...

Страница 7: ... Cause Solution Digital display is dim Battery in electronic control is worn out Replace battery See page 8 Electronic control is malfunctioning Replace the electronic control Order Part No 24V554 Digital display does not activate Battery in electronic control is worn out Replace battery See page 8 Electronic control is malfunctioning Replace the electronic control Order Part No 24V554 There is no...

Страница 8: ...screwdriver or similar tool between the battery and the positive terminal bat tery retainer in the electronic control to remove the battery as shown in FIG 8 5 Insert the new battery with the negative side of the battery position to the bottom of the battery holder Press the battery firmly down until the positive ter minal clips above the battery See FIG 9 Battery Side View to identify the negativ...

Страница 9: ...he cover off Remove and discard the screws 6 Lift off the electronic control 3 Remove and discard the large o ring 4 screws and electronic control according to all standards for disposal 4 Install the new large o ring 4 over the lip on the top of the metering unit 2 Align the notch on the side of the new electronic control module 3 with the notch on the side of the metering unit 2 5 Install new sc...

Страница 10: ...cluded in Kit 24V554 This kit also includes a disposable grounding strap not shown Underside view 1 6 3 4 2 7 Ref Part Description Qty 1 191782 GUARD impact 1 2 METERING UNIT gal lon quart pint liter 1 3 24V554 KIT electronic control 1 4 109137 O RING 1 6 112093 SCREW 6 7 BATTERY ...

Страница 11: ...ressure Loss Tested in 10W oil at 70 F 21 C Flow rate varies with fluid pres sure temperature viscosity 150 psi 12 gpm 1 03 MPa 10 3 bar 45 4 lpm Weight 1 9 lb 0 95 kg Units of measurement Factory set in quarts Display shows quantity in 0 01 incre ments up to 199 99 gallons quarts pints or liters Total dis plays up to 19 999 units Inlet and outlet 1 2 npt non directional flow Operating temperature...

Страница 12: ...not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation Disclaimers and Limitations The terms of this warranty constitute purchaser s sole and exclusive remedy and are in lieu of any other warranties express or implied including warranty of merchantability or warranty of fitness for a parti...

Отзывы: