Operation
334852D
5
Setup Mode
1.
Press the TOTAL and RESET buttons (F
together.
•
All segments of the digital display
illuminate for approximately 4 seconds.
•
The software revision displays for approximately
1 second.
•
The meter goes blank and the volume unit
blinks.
The meter is now in Setup Mode.
2.
Release the TOTAL and RESET buttons.
Volume Unit
3.
The default Unit of Measure (UOM) is Quarts (QTS).
Repeatedly press the TOTAL button (F
. 2) to
change the displayed UOM. F
. 4 shows examples
of each UOM screen.
4.
When the desired UOM is displayed, press the
RESET button (F
. 2) to save the selection.
5.
CAL appears on the display as shown in F
. 5. CAL
indicates the meter is ready for Calibration Mode.
6.
If you do not want to Calibrate the meter, to exit
Setup, press the RESET button again. To Calibrate
the meter, see Calibration Mode instructions in the
following section of this manual.
Calibration Mode
•
The meter has a preset calibration factor from the
factory.
From the CAL screen:
NOTE:
Instructions for displaying the CAL screen are
provided in Setup Mode, steps 1 - 5.
1.
To save the current Calibration factor, press RESET
and the unit will save and exit setup.
2.
To recalibrate the meter:
a.
Dispense 1 Quart (or 1 Liter) of fluid into a
clean, calibrated container.
b.
When the volume of fluid in the calibrated con-
tainer reaches 1 Quart (or 1 Liter), stop the dis-
pense.
NOTE:
During the dispense the numbers on the
display and the UOM flash on the screen.
c.
Press and hold the TOTAL button until 1.00 QTS
(or 1.00 L) displays steady on the screen. F
shows the meter displaying 1.00 QTS has been
dispensed.
d.
If you are satisfied with the dispense, press the
RESET button to save the new calibration factor
and exit the Setup Mode.
e.
If the dispense was not accurate and needs to
be performed again, repeat Step 2, a - d.
F
IG
. 4: Example of Units of Measure (UOM)
F
IG
. 5
F
IG
. 6