Installation
333233D
5
Installation
Power Supply
See
Table 1
for power supply requirements. The system
requires a dedicated circuit protected with a circuit
breaker.
Select the minimum cord wire gauge based on length
according to the table below:
Connect Power
1.
Cut power cord wires to the following lengths:
•
Ground wire - 6.5 inches (16.5 cm)
•
Power wires - 3.0 inches (7.6 cm)
•
Add ferrules as necessary. See F
2.
Bring cord to unit and remove four screws to sepa-
rate junction box cover (G) with power switch (E)
from remainder of sprayer. See F
. 2.
3. With power switch (E) and junction box cover (G)
detached from machine, wires inside junction will
appear as below.
NOTE:
Two wires will be installed in both terminals.
See F
•
For Series A and B: terminals 1L1 and 3L2
•
For Series C: terminals 1L1 and 5L3
NOTE:
Press gasket against back sealing face of
junction box to ease installation of power cord.
4.
Insert power cord (from step 1) through cord grip
(C2) and into junction box (S).
NOTE:
Power wires should be installed into termi-
nals. See F
. 3:
•
Series A and B: terminals 2T1 and 4T2
•
Series C: terminals 2T1 and 6T3
Improper wiring may cause electric shock or other
serious injury. All electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Table 1: Power Supply Specifications
Voltage
Phase
Hz
Current
200-240 VAC
1
50/60
20 A
Length
Gauge
mm
2
50 ft (15.24 m)
12 AWG
3.31
100 ft (30.48 m)
10 AWG
5.26
200 ft (60.96 m)
6 AWG
13.29
300 ft (91.44 m)
4 AWG
21.14