Available Internal Data
3A1704N
19
32,
33,
34,
35
Double
Integer
Flow Rate Actual: Integer value of the actual Flow Rate.
The value from the CGM is an integer and must be multiplied by 0.0001 for the actual flow
rate to be in system units.
Example: Double word 259876 = 25.9876cc/sec (unit chosen is cc/sec)
36,
37
Integer
Ratio Value Actual: Integer value of the actual Material Ratio. Note this only can be moni-
tored if the ratio monitoring option (flow meters) is installed.
The value from the CGM is an integer and must be multiplied by 0.01 for the actual ratio to
be in system units. xx.xx : 1 where xx.xx is Red and 1 is Blue.
Example: Word 36 = 2368 = 23.68:1
38,
39,
40,
41
Double
Integer
Dispense Amount Actual: Integer value of the actual dispense amount (shot size).
The value from the CGM is an integer and must be multiplied by 0.001 for the actual dis-
pense amount to be in system units.
Example: Double word 875240 = 875.240cc (unit chosen is cc)
42,
43,
44,
45
Double
Integer
Dispense Duration Actual: Integer value (mS) if the actual time the dispense lasts.
The value from the CGM is an integer in milliseconds (1 second = 1000 mS).
Example: Double Word 5695 = 5695mS = 5.695 sec
46,
47
Integer
Blue Inline Temperature Actual: Integer value of the actual Blue inline temperature.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 46 = 1025 = 102.5°F (unit chosen is °F)
48,
49
Integer
Blue Hose Temperature Actual: Integer value of the actual Blue hose temperature.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 48 = 1056 = 105.6°F (unit chosen is °F)
50,
51
Integer
Red Inline Temperature Actual: Integer value of the actual Red inline temperature. Depend-
ing on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 50 = 985 = 98.5°F (unit chosen is °F)
52,
53
Integer
Red Hose Temperature Actual: Integer value of the actual Red hose temperature. Depend-
ing on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 52 = 780 = 78.0°F (unit chosen is °F)
54,
55
Integer
Blue Tank Temperature Actual: Integer value of the actual Blue tank temperature. Depend-
ing on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 54 = 1157 = 115.7°F (unit chosen is °F)
56,
57
Integer
Red Tank Temperature Actual: Integer value of the actual Red tank temperature. Depend-
ing on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 56 = 322 =32.2°C (unit chosen is °C)
58,
59
Integer
Blue Chiller Temperature Actual: Integer value of the actual Blue chiller temperature.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 58 = 345 = 34.5°C (unit chosen is °C)