Available Internal Data
20
3A1704N
60,
61
Integer
Red Chiller Temperature Actual: Integer value of the actual Red chiller temperature.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 60 = 238 = 23.8°C (unit chosen is °C)
62,
63
Integer
Blue Inline Temperature Set Point: Integer value of the Blue inline temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 62 = 1000 = 100.0°F (unit chosen is °F)
64,
65
Integer
Blue Hose Temperature Set Point: Integer value of the Blue hose temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 64 = 950 = 95.0°F (unit chosen is °F)
66,
67
Integer
Red Inline Temperature Set Point: Integer value of the Red inline temperature set point.
Depending on the system set up this is read in °C or °
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 66 = 900 = 90.0°F (unit chosen is °F)
68,
69
Integer
Red Hose Temperature Set Point: Integer value of the Red hose temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 68 = 1100 = 110.0°F (unit chosen is °F)
70,
71
Integer
Blue Tank Temperature Set Point: Integer value of the Blue tank temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 70 = 1050 = 105.0°F (unit chosen is °F)
72,
73
Integer
Red Tank Temperature Set Point: Integer value of the Red tank temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 72 = 300 = 30.0°C (unit chosen is °C)
74,
75
Integer
Blue Chiller Temperature Set Point: Integer value of the Blue chiller temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 74 = 320 = 32.0°C (unit chosen is °C)
76,
77
Integer
Red Chiller Temperature Set Point: Integer value of the Red chiller temperature set point.
Depending on the system set up this is read in °C or °F
The value from the CGM is an integer and must be multiplied by 0.1 for the actual tempera-
ture.
Example: Word 76 = 350 = 35.0°C (unit chosen is °C)
78
0
Bit
Tank Material Level Status: The state of the level switches on the tank.
76543210 (bits)
00000001 = Red Tank Level Low On
00000010 = Red Tank Level Middle On
00000100 = Red Tank Level High On
00010000 = Blue Tank Level Low On
00100000 = Blue Tank Level Middle On
01000000 = Blue Tank Level High On
1
2
3
4
5
6
7
Byte
Bit
Data
Type
State or
Range