Available Internal Data
3A1704N
21
79,
80,
81,
82
ASCII
Errors requiring acknowledgment are presented on first in first out basis. The latest error is
currently in the error register in the CGM. The PLC must send back the exact ASCII value
for the error to be acknowledged in the CGM. If an incorrect ASCII error code is sent back to
the CGM then the error will not clear and the CGM register will be overwritten with the incor-
rect error. If multiple error codes exist, then the PLC must acknowledge them in the order
the errors are sent to the PLC from the CGM.
ASCII value for each Byte: Example Error L6A1 = Red Auto Fill Refill Timeout:
Byte 79 = L
Byte 80 = 6
Byte 81 = A
Byte 82 = 1
83
0
Bit
Not Used
0
N/A
1
N/A
1
Not Used
0
N/A
1
N/A
2
Not Used
0
N/A
1
N/A
3
Not Used
0
N/A
1
N/A
4
ADM Status: System Power Status
0
Power OFF
1
Power ON
5
ADM Status: Dispense System Ready to Dispense
0
Not Ready
1
Ready
6
ADM Status: Dispense System Ready for External Requests
0
Not Ready
1
Ready
7
Not Used
0
N/A
1
N/A
Byte
Bit
Data
Type
State or
Range
CGM Outputs to PLC Inputs for Monitoring Description