308442 11
Installation
Connect the Air and Fluid Lines
See Fig. 1 and 2, page 8, for a schematic of air and
fluid connections. Connect the air and fluid lines to the
gun manifold as instructed at right.
Graco Electrically Conductive Air Hose
WARNING
ELECTRIC SHOCK HAZARD
To reduce the risk of electric shock or
other serious injury, the air supply hose
must be electrically connected to a true
earth ground. Use Only Graco Electrically Con-
ductive Air Supply Hose.
Connect the Graco electrically conductive air hose (B)
to the gun turbine air inlet and connect the hose
ground wire (A) to a true earth ground. See Fig. 1,
page 8. Check the electrical grounding of the gun as
instructed on page 14.
NOTE: The hose and the gun have special left-hand
threads to prevent connecting another type of air hose
to the gun turbine air inlet.
Graco Electrically Conductive Air Hose
Required for gun operation.
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
0.315 in. (8 mm) ID; 1/4 npsm(f) x 1/4 npsm(f) left-hand
Part No.
Length
Black Hose
Grey Hose
Red Hose
6 ft. (1.8 m)
15 ft. (4.6 m)
25 ft. (7.6 m)
36 ft. (11.0 m)
50 ft. (15.2 m)
75 ft. (23.0 m)
100 ft. (30. 5 m)
220444
218100
218101
218102
218103
220119
220120
223068
223069
223070
223071
223072
223073
223074
235068
235069
235070
235071
235072
235073
235074
Black Hose: standard hose, semi-conductive nylon core,
urethane outer
Grey Hose: more flexible (less durable) than black hose,
modified semi-conductive polyamide core, urethane cover
Red Hose: conductive SST wire braid for grounding, polyure-
thane tube and cover
Fluid Line
Before connecting the fluid line, blow it out with air and
flush it with solvent. Use solvent that is compatible with
the fluid being sprayed.
Manifold Connections (See Fig. 5)
A1
Atomization Air Inlet Fitting
Connect a 3/8 inch O.D. tube between the fitting and
the air supply.
A2
Fan Air Inlet Fitting
Connect a 3/8 inch O.D. tube between the fitting and
the air supply.
CYL Cylinder Air Inlet Fitting
Connect a 1/4 inch O.D. tube between this fitting and
the solenoid. For quicker trigger response, use the
shortest hose length possible.
EXH Shroud Exhaust Outlet Fitting
Connect a 1/4 inch O.D. x 4 foot (1.22 m) long tube to
the fitting.
F.O.
Fiber Optic Fitting (Optional)
Connect the Graco Fiber Optic Cable as instructed on
page 12.
KV
kV Switch Air Inlet Fitting
Connect a 1/4 inch O.D. tube between the fitting and
the air solenoid.
P1
Fluid Supply Inlet Fitting
Connect a 1/4 inch npsm swivel fitting between the
fitting and the fluid supply.
P2
Fluid Return Inlet Fitting (Optional)
Connect 1/4 inch O.D. tube between the fitting and the
dump valve for recirculation.
TA
Turbine Air Inlet Fitting
Connect the Graco Electrically Conductive Air Hose
between this fitting (left-hand thread) and the solenoid.
Connect the air hose ground wire to a true earth
ground.
03213
Manifold Back View
TA
CYL
A1
P1
KV
A2
EXH
F.O.
P2
Fig. 5