Robot Mounting Flange
1. Attach the mounting flange onto the sixth axis of the
robot with the required bolts supplied with the
Switch 3D Gun mounting kit.
2. The mounting flange is then attached to the body of
the Switch 3D Gun with three M6x20 hex socket
screws. Torque to 98.2 in-lbs (11.1 N•m). It is
important to make sure the 6mm guide pins
supplied with the kit are inserted into the correct
positions. See F
Anti-Rotation Brackets
After the Switch 3D Gun is mounted to the robot, the
anti-rotation brackets must be attached to the swivel
housing (619) and to the fixation point on the robot using
the hex head screws. Exact fitting of the anti-rotation
brackets will depend on the robot and kit being used.
See F
. 3 for installation example and page 28 for
swivel chamber part reference.
Nozzles
NOTE:
Nozzles are not supplied with the Switch 3D Gun
and must be purchased separately to match customer
specifications. See
options.
1. Place three nozzle packing gaskets (303) into
matching recess’s of the nozzle head (301).
2. Nozzles (302) must be inserted in the nozzle cap
(305) making sure the nozzle is keyed into the
nozzle cap.
3. The nozzle cap with the nozzles inserted, must be
firmly fixed to the nozzle head (301) using the M6
hex button head screw (306) in the center of the
cap. Torque to 29.2 in-lbs (3.3 N•m). See F
Cable Connections
NOTE:
Cables and hoses are attached only after Switch
3D Gun is bolted to robot.
Connect cable (1001 or 1002) to the Switch 3D Gun,
then connect other end of the cable by making the
appropriate connections to the robot’s control cabinet.
See F
See the
table page 3, for the cable type needed
for your Switch 3D Gun mode.
F
IG
. 2
F
IG
. 3
6mm guide
pins
M6 x 20 hex
socket screws
Anti-Rotation
Brackets
Swivel chamber
F
IG
. 4
302
303
306
305