m908 User Manual, Rev. G
Each input can be custom defined in the Setup Menu. The hardware connector, channel count,
level offset, sync delay, clock override mode, and name can be configured. See the
section of this manual for details.
5.4.1 Input Summing Mode
The m908 allows up to three inputs to be summed. To enter summing mode, simultaneously
press the INPUT select switches for up to three of the desired inputs to sum. The inputs will
become active at the same time and the name areas will turn green on the display.
To change the inputs that are being summed press the INPUT select switches for the channels
that are to be removed from the sum then press the INPUT select switches for the channels that
are to be added to the sum.
Pressing any of the active INPUT select switches will toggle that input on and off in the sum.
To exit input summing mode simply de-select the inputs that you don't want in the sum. When
only one input is active push that switch and summing mode will turn off. The input name area
will be displayed in blue.
Any input that has
clock override
enabled can not be summed with other inputs unless all
inputs share the same clock override source. Attempting to sum inputs that have different clock
sources will cause the following message to appear:
Page 24 of 135
Illustration 11: Input Page Select
Illustration 12: Input Summing Mode