![GPO Display NEX Series Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/gpo-display/nex-series/nex-series_user-manual_2248937013.webp)
13
www.gpodisplay.com
NEX-series Video wall
Connect RS-232 Cables*
*See pg.43-44 for network control setup instructions.
1. While mounting display, insert any cables used for Power, video inputs or outputs into the set.
2. Prior to insertion of the next set into neighboring Wall Unit, insert cables (including RS-232) from the outputs of the first set into
the inputs of the second set.
3. Repeat steps 1-2 for next set, if necessary.
4. The RS-232 daisy chain limitation is listed as 30 displays, although theoretically more units can be accommodated.
5. Daisy-chaining can be initiated from any unit but
it is strongly recommended that you start with a display on the bottom row
for
ease of access. There is no terminator at the end of the unit. It is always recommended to record/make note of the chaining diagram
as it is crucial to diagnosing issues with communication.
Cabling Set up
Set ID #1
Set ID #2
Set ID #3
Set ID #4
Set ID #5
Set ID #6
Set ID #7
Set ID #8
Set ID #9
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RS232 Out
RS232 IN
RJ45 Input OR RS232 input