To ensure safe operation, all transfer systems must be
properly grounded. Proper grounding means a continuous
metal-to-metal contact from one component to the next,
including tank, bung, pump, meter, filter, hose and nozzle.
Care should be taken to ensure proper grounding during initial
installation and after any service or repair procedures. For
your safety, please take a moment to review the warnings below.
Observe precautions against electrical shock when operating
the system. Serious or fatal shock can result from operating
electrical equipment in damp or wet locations.
Inspect external pump wiring regularly to make sure it is
correctly attached to power supply. To avoid electrical shock,
use extra care when connecting the pump to power.
Avoid prolonged skin contact with DEF. Use protective goggles,
gloves and aprons in case of splashing or spills. Change satu-
rated clothing and wash skin promptly with soap and water.
Observe precautions against electrical shock when servicing
the pump.
Always
disconnect power before repairing or ser-
vicing.
Never
apply electrical power to the system when any
of the coverplates are removed.
PA-120DEF:
• This pump is designed for use with GFCI protected, 115-volt
power. Do not attempt installation or operation with 12-volt,
24-volt, or 230-volt power sources. Use only three-pronged,
grounded connectors. Do not use two-prong adapters.
Inspect power cords regularly and replace if signs of wear
are evident.
• To avoid personal injury, use a ground fault circuit interrupter
(GFCI) approved by Underwriters Laboratories Standard
943 with this pump.
To protect against overload, this pump is equipped with a ther-
mal protector, that resets automatically, and a circuit breaker,
that resets manually. If your pump stops unexpectedly, please
reference further information about the thermal protector and
circuit breaker in the Operations or Troubleshooting Sections.
P-120DEF:
This pump is designed for use with a 12-volt DC battery.
• Inspect wiring regularly. Make sure the power cord is cor-
rectly attached to the battery. To avoid electrical shock,
use extra care when connecting the pump to the battery.
PA-120DEF & P-120DEF:
• Do not exceed standard duty cycle of 30 minutes ON and
30 minutes OFF. Allow the pump to cool for 30 minutes.
• Some fluid may spill from the pump during pump removal.
Follow DEF label directions for cleanup and disposal.
• Do not run the pump more than necessary without flow.
“Dry running” can cause overheating and pump damage.
• To avoid personal injury, turn the pump off and disconnect
from power before repair or service.
• For your protection, thoroughly flush the pump before
cleaning or repair.
When you receive your pump, examine it for visible damage. If any
items are damaged or missing, please contact your distributor.
GENERAL INFORMATION
The purpose of this manual is to assist you in installing, op-
erating and maintaining your GPI pump. It provides information
which will help you achieve years of dependable performance
and trouble-free operation.
The system is approved for DEF (Diesel Exhaust Fluid)
only
.
Do not use with gasoline, diesel, other flammable fluids, or
micro-encapsulated fluids. Using fluids, other than those for
which the pump was designed, could lead to serious personal
injury and void the warranty.
Before operating your pump, read this manual thoroughly. If
you have problems with your pump in the future, please refer
to the Maintenance and Troubleshooting Sections.
For assistance, contact your dealer or the GPI Customer
Service Department.
The following safety alert symbols are used
in this manual.
DANGER indicates a hazard-
ous situation which, if not
avoided, will result in death
or serious injury.
WARNING indicates a haz-
ardous situation which, if
not avoided, could result in
death or serious injury.
CAUTION indicates a haz-
ardous situation which, if not
avoided, may result in minor
or moderate injury.
It is your responsibility to:
• know and follow applicable national, state, and local safety
codes pertaining to installing and operating electrical
equipment.
• insure that all equipment operators have access to adequate
instructions concerning safe operating and maintenance
procedures.
Observe all safety precautions concerning safe handling of DEF.