12
SPECIFICATIONS
PA-120DEF:
Applications
Fluids: Diesel Exhaust Fluid (DEF)
Operating Environment: Outdoor, operating temperature range
of –20° to +120° F (–30° to +50° C).
Operating Pressure
10 PSI
Pump Housing
Lightweight, durable, molded plastic housing.
Convenient 2-inch NPS bung adapter for easy
installation.
Performance
Pump Rate: Up to 12 GPM (45 LPM). Rate will vary with
temperature.
Duty Cycle: 30 minutes ON, 30 minutes OFF. Duty cycle will
vary with temperature.
Electrical Specifications
Input: 115-volt AC, grounded, GFCI protected
Cord: 18 gauge, 3 wire, grounded plug equipped with circuit
breaker.
Mechanical Connections
Bung: 2 inch NPS
Inlet:
1 inch NPT
Outlet: 1 inch NPT
Recommended Accessories
3/4 in. x 12 ft. (3.7m) DEF discharge hose
3/4 in. NPT DEF automatic nozzle
3/4 in. NPT DEF ball valve
Weight
Shipping: 15 lbs. (6.8kg)
P-120DEF:
Applications
Fluids: Diesel Exhaust Fluid (DEF)
Operating Environment: Outdoor, operating temperature range
of –20° to +120° F (–30° to +50° C).
Operating Pressure
10 PSI
Pump Housing
Lightweight, durable, molded plastic housing.
Convenient 2-inch NPS bung adapter for easy
installation.
Performance
Pump Rate: Up to 12 GPM (45 LPM). Rate will vary with
temperature.
Duty Cycle: 30 minutes ON, 30 minutes OFF. Duty cycle will
vary with temperature.
Electrical Specifications
Input: 12-volt DC
Current: 12-15 amps
Cord: 14 gauge, 15 ft. (4.6m)
Fuse: 20 amps AGC
Mechanical Connections
Bung: 2 inch NPS
Inlet:
1 inch NPT
Outlet: 1 inch NPT
Recommended Accessories
3/4 in. x 12 ft. (3.7m) DEF discharge hose
3/4 in. NPT DEF automatic nozzle
3/4 in. NPT DEF ball valve
Weight
Shipping: 15 lbs. (6.8kg)