23
Pump flow is too low
There is no suction
×
Wrong direction of rotation
×
Valves are not opened
×
enough
Impurities in the pipe work
×
Pump draws air
×
Air pockets in the suction
×
line
Wrong motor connection
×
×
See above
×
Change two terminals
×
Open valves
×
Clean pipes
×
Stop leakages in suction
×
line, raise level in suction
tank
Deaerate
×
Reconnect in the right way
×
Pump produces low pressure
Wrong direction of rotation
×
Cavitation
×
Motor is running too slow
×
(fre quency converter)
Wrong motor connection
×
Change two terminals
×
See below
×
Raise frequency
×
Reconnect in the right way
×
Cavitation (pumps make a
cracking noise, floating of the
pump pressure)
Friction losses in suction
×
line too high
Liquid temperature too
×
high
Liquid level in suction tank
×
too low
All valves in suction line
×
must be completely open,
enlarge diameters
Cool down liquid
×
Fill up tank or lower pump
×
Pump flow too high
Friction losses too low
×
Close valve in discharge
×
pipe
Pump blocked
Pump wrongly assembled
×
Foreign body in the pump
×
Disassemble and assemble
×
in the correct way
Clean
×
Motor uses too much current
(Amperes)
Wrong direction of rotation
×
Flow too high
×
Pump blocked
×
Voltage too low
×
Change two terminals
×
See above
×
See above
×
Repair electrical failure
×
Motor overheats
Motor uses too much
×
current
Ambient temperature too
×
high
Not enough cooling
×
See above
×
Cool down
×
Do not let the motor run
×
slower than on 25 Hz, im
prove air supply
Pump vibrates
Cavitation
×
Pump draws air
×
Motor bearings worn
×
See above
×
Stop leakages in suction
×
line, raise level in suction
tank
Replace motor (bearings)
×
Pump leaks
Mechanical seal broken
×
Pump casing seal broken
×
Replace mechanical seal
×
Replace pump casing seal
×
Pump makes abnormal noise
Cavitation
×
Two touching parts or
×
pumps blocks
Pump flow too high
×
Motor bearings worn
×
See above
×
See above
×
See above
×
Replace motor (bearings)
×