Device Description HG G-71910-C | English, Revision 03 | Date: 17.09.2019
29
Components and Operation – Chapter 5
Table 31
Identity Object
Index Sub Index Name
Type
Attr. Map Default
Meaning
1018 00
Identity Object Unsigned 8 RO
No
0x03
Number of Sub Indexes
01
Vendor ID
Unsigned 32 RO
No
0x00000202 manufacturer number
determined by the CiA®
02
Product Code Unsigned 32 RO
No
0x00071910 HG number 71910
03
Revision
Unsigned 32 RO
No
0x00000003 Version 3
04
Serial Number Unsigned 32 RO
No
99999
Serial number
Table 32
Transmit PDO_1 Parameter
Index Sub Index Name
Type
Attr. Map Default
Meaning
1800 00
TxPDO
Parameter
Unsigned 8 RO
No
0x05
Number of Sub Indexes
01
COB ID
Unsigned 32 RW
*)
No
0x40000180
+ Node-ID
PDO_1 valid, ID = 0x180
+ Node-ID
02
Transmission
Type
Unsigned 8 RW
No
1..240,255
Synchronous or asyn
-
chronous
03
Inhibit Time
Unsigned 16 RW
No
10
shortest time between
two transmissions in ms
04
Dummy
05
Event Time
Unsigned 16 RW
No
100
Cycle time in ms
*) Here only the highest bit can be changed in order to temporarily (de)activate the PDO.
Table 33
Transmit PDO_2 Parameter
Index Sub Index Name
Type
Attr. Map Default
Meaning
1801 00
TxPDO
Parameter
Unsigned 8 RO
No
0x05
Number of Sub Indexes
01
COB ID
Unsigned 32 RW
*)
No
0x40000180
+ Node-ID
PDO_2 valid, ID = 0x280
+ Node-ID
02
Transmission
Type
Unsigned 8 RW
No
1..240,255
Synchronous or asyn
-
chronous
03
Inhibit Time
Unsigned 16 RW
No
10
shortest time between
two transmissions in ms
04
Dummy
05
Event Time
Unsigned 16 RW
No
100
Cycle time in ms
*) Here only the highest bit can be changed in order to temporarily (de)activate the PDO.