Device Description HG G-71910-C | English, Revision 03 | Date: 17.09.2019
20
Chapter 5 – Components and Operation
Example:
Error
0006 stands for CODE_CRC_ERR and CODE_PAR_ERR.
Errors
0002
and
0004
may also arise during ordinary transponder crossings, if the
code transmission is aborted due to decreasing power output level.
5.2.2.1.2 List of System Commands
A Command telegram always consists of four bytes, including the command itself,
its parameters and at last the check sum (XOR relation of all bytes with starting sign).
When choosing the procedure "transparent" (see appendix, section 9.3 on page 49)
a start sign has to be sent as well.
The monitor mode should not be used during normal operation (e.g. from a PLC) as
the following output is not carried out according to a transparent or 3964 R protocol
but only suitable for display on a VT 52- terminal and used for the manual alteration
of parameters.
There are 3 predefined commands:
0040
0080
0100 RW_TRANSPON
-
DER
Transponder is writeable *)
0200 TRANS_IN_FIELD Transponder is detected *)
0400 CODE_OK
Decoded code correct *)
0800 SEGMENT-
A transponder is located under the connector / cable
side of the antenna
1000 POSIPULS
Transponder has crossed the center of the antenna *)
2000
4000
8000 RESET
Set after antenna is switched on *)
*) These bits are deleted when the transponder leaves the antenna field.
Table 7
Possible system status / error messages (part 2 of 2)
Value Name
Description