Device Description HG G-71910-C | English, Revision 03 | Date: 17.09.2019
28
Chapter 5 – Components and Operation
By writing the signature
save
or
evas
in ASCII-Code (hex-Code: 0x65766173) on
Sub Index 1 the current parameters are permanently saved. A successful saving op
-
eration is acknowledged via TxSDO (1. Byte = 0x60) after approx. 300 ms. While the
saving operation takes place no CAN telegrams can be sent or received.
By writing the signature
load
or
daol
in ASCII-Code (hex-Code: 0x64616F6C) to
Sub Index 1, 2 resp. 3 the corresponding default parameters are loaded. Afterwards
an antenna reset should be carried out. In addition "Restore All" sets the Node-ID to
1 and the baud rate to 125 Kbaud.
Setting the time to 0 disables this function.
Table 25
Manufacturer Device Name
Index
Sub
Index
Name
Type
Attr. Map
Default
Meaning
1008
00
Manufacturer
Device Name
Visible String
RO
No
7191
Device name
Table 26
Manufacturer Hardware Version
Index Sub
Index Name
Type
Attr. Map Default
Meaning
1009
00
Manufacturer Hard
-
ware Version
Visible String
RO
No
A6
Board version
Table 27
Manufacturer Software Version
Index Sub
Index Name
Type
Attr. Map Default Meaning
100A
00
Manufacturer Soft
-
ware Version
Visible String
RO
No
1.43
Software version
Table 28
Save Parameter
Index Sub Index Name
Type
Attr. Map Default
Meaning
1010 00
Save Parameter Unsigned 8 RO
No
0x01
number of sub indexes
01
Save All
Unsigned 32 RW No
0x00000001 Save All is possible
Table 29
Restore Default Parameter
Index Sub Index Name
Type
Attr. Map Default
Meaning
1011 00
Restore Param
-
eter
Unsigned 8 RO
No
0x03
Number of Sub Indexes
01
Restore All
Unsigned 32 RW No
0x00000001 Restore All is possible
02
Restore Com
-
munication
Unsigned 32 RW No
0x00000001 Restore Communication
is possible
03
Restore Manu
-
facture
Unsigned 32 RW No
0x00000001 Restore Manufacture is
possible
Table 30
Producer Heartbeat Time
Index Sub Index Name
Type
Attr. Map Default Meaning
1017 00
Producer Heart
-
beat Time
Unsigned 16 RW No
1000
Heartbeat Time in ms
(approx.)