Components and Operation
Revision 04 (English), Date: 26.04.2016
6
2.2
The Installation Components
2.2.1
Loop Adaptor HG 94210
The loop adaptor is contained within an aluminium casing, size 120 x 122 x 91 mm. It
is fitted with two PG plugs, one for the RG 213 coax cable from the generator and the
other for both ends of the loop conductor 2,5 mm². The casing should be earthed as
the voltage over-load is connected to it.
The Coax Cable RG 213 should not be longer than 30 m and the loop conductor to the
guide wire should not be longer than 10 m in length.
Connection
Function
1
Loop
2
Coax RG213 core (from Generator)
3
Coax RG213 shield (from Generator)
4
Loop
Casing
Ground
Table 1
Connection Plan for the Loop Adaptor
35
122
120
30
PG9
PG16
10
Ø4
(Gesamthöhe) 91mm
X2
X1
1
3
2
4
1
5
To
tal height 91 mm