Mounting
Revision 04 (English), Date: 26.04.2016
13
3
Mounting
3.1
Mounting Instructions for Guide Wire
Figure 3
Guide Wire Layout
•
By a layout as shown in the diagram no adaptor resister is required.
•
The guide wire should be set in the ground at a depth of 30 to 40 mm.
•
The iron free area around the guide wire should be
- left and right of guide wire:
approx. 400 mm
- parallel to tracks or large metal objects and metal reinforcement within the track:
±800 mm
- below the guide wire:
ca. 100 mm
3.2
Mounting the loop adaptor HG 94210
The loop adaptor is fitted into an aluminium casing. The casing should be earthed as
the voltage peak cable is earthed to this casing. The casing should be mounted with
the PG plugs downward most and fitted to a mast. In order to mount the loop adapter
the lid has to be removed. 4 x M 5 positions have been prepared for this.
3.3
Mounting the Track Guidance Generator HG 57400
The track guidance generator is to be fitted into a suitable cabinet, so that the temper-
ature range of 0 to 50
o
C can be kept. If the generator is not turned off then a temper-
ature of up to -20
o
C is allowable.