background image

11

 

 Power Switch

 

Power Switch located on the bottom of GoTemp is 
turned OFF to minimize battery drain. Use a small 
plastic pin to switch the power button ON before 
operation.

 

Five orange blinks appear at power up. Make sure 
the LEDs are working, otherwise, plug charger and 
expect flashing orange light.

 

Power button can be turned off if GoTemp is not 
used for long time, which will save battery and 
extend its life.

 

 Mounting Brackets

 

Four mounting brackets are provided for iPhone 5/5s, iPhone 6, iPhone 6+ and 
adjustable bracket for use on all other phones.

 

After turning the switch ON, position the bracket and push it in the guiding grooves 
to snap in place. Push the bracket in opposite direction to remove.

 

Содержание THB4002

Страница 1: ...THB4002 GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide Provided by Measuring Temperature The Smart Way ...

Страница 2: ... to Spot 4 Reset 5 Indicators 5 Specifications 7 Proper Application and Operation 9 Power Switch 11 Mounting Bracket 11 Maintenance 13 Laser Safety 16 Other Operational Considerations 13 Certifications 18 FCC Compliance Statement 20 Bluetooth Pairing 6 IC Warning 21 ...

Страница 3: ...measure internal temperatures GoTemp is a battery operated device and can be recharged via the standard micro USB connector from any computer or 5V charger A K type thermocouple connect or is used to connect the insertion probe The interface of the device is minimal as it includes an illuminated push button to provide ability to reset and give feedback about device status and a slide switch to tur...

Страница 4: ...or portion of food product that is being measured thermally The distance of the infrared thermometer from the target determines the dimension of this area The further away from the target the larger is the area being measured The ideal working range of GoTemp is between 25 mm and 300 mm 1 and 12inch es The laser pointer helps to indicate the measurement spot To ensure accurate measurements the mea...

Страница 5: ...s are lit simultaneously Indicator reflects the device state and warns you if battery is getting low or there is not enough charge to power device Green color indicates full battery orange means that battery is low and red means battery is empty Blinking light means the device is connected to a phone You can always check the battery percentage and charging state on the phone s display Refer to the...

Страница 6: ...th smartphone before the first use Every GoTemp device has a unique identifier printed on the back it is known as MAC The Mobile App will automatically connect to the available GoTemp if there is only one GoTemp found in the range otherwise a list will pop up for the user to select the device to be used The names of available GoTemp devices show up as GOTEMP_XX with XX denoting the last two digits...

Страница 7: ... C 14 113 F Operating Temperature 10 40 C 50 104 F Humidity 10 90 RH Charging Current 100mA Charging Voltage 5V Battery Parameter Value Capacity 400 mAh Voltage 3 7V Lifetime 360 hours Standby 16 hours measuring Laser Parameter Value Peak Wavelength 650nm Optical Power 1mW Bluetooth Power 0dBm ...

Страница 8: ...curacy Response Time 1 second Infrared Temperature Parameter Conditions Value Measurement range 10 120 C 14 250 F Resolution 0 1 C 0 1 F Typical Measurement Distance 25 300mm 1 12 Distance to Spot 12 1 Accuracy at room temperature 25 C Object temperature 0 60 C 0 5 C 2 F Accuracy at room temperature 25 C Object temperature 0 C or 60 C 1 C 4 F Repeatability Within accuracy Response Time 1 second ...

Страница 9: ...cannot measure through transparent surfaces such as glass and plastic It will measure the surface temperature of the glass or plastic instead Remove Trans parent Covers Before Measur ing Steam dust smoke and or vapors can prevent accurate measurement by obstructing the unit s optics Please refer to maintenance section for cleaning in case any of these conditions happened Keep Unit Clean Infrared t...

Страница 10: ...lue by referring to the emissivity table GoTemp emissivity can be changed from 0 1 to 1 0 in 0 01 steps refer to instruction in the mobile app to modify emissivity Most Food Products Do Not Require Change of Emissivity GoTemp is designed to work between 10 C and 40 C 50 104 F In case a change in temperature happened like walking in out of walk in freezer the unit must not be used for at least 15 m...

Страница 11: ...ise plug charger and expect flashing orange light Power button can be turned off if GoTemp is not used for long time which will save battery and extend its life Mounting Brackets Four mounting brackets are provided for iPhone 5 5s iPhone 6 iPhone 6 and adjustable bracket for use on all other phones After turning the switch ON position the bracket and push it in the guiding grooves to snap in place...

Страница 12: ...12 ...

Страница 13: ...ommended Materials needed 1 Aluminum container beverage can 2 Matte black spray paint or matte black self adhering paper appliqué Masking tape may also be used 3 Temperature standard thermometer Other Operational Considerations GoTemp is protected from the following EMI Electro Magnetic Interference from induction heaters and microwave ovens Electrostatic discharge Should the unit become damaged c...

Страница 14: ...llow the can and temperature standard ther mometer to come to equilibrium 2 Take a reading with the IR thermometer Do not exceed the spot size of the IR thermometer as indicated on the unit 3 Compare the temperature reading of the IR unit with the temperature stand ard thermometer 4 Repeat this procedure using hot water If the temperature deviation exceeds accuracy limit return the unit for repair...

Страница 15: ...the lens you would need two lint free cotton swabs Moist a cotton swab and insert it in the aperture to scrub the deep lens then repeat the same using the dry cotton swab To clean the unit itself wipe it down with a moist cloth using water based mild detergent Warning Do not submerse the unit or wash in dishwasher Cleaning Instructions ...

Страница 16: ... specifications in specification section Warning 1 Avoid direct exposure of human eyes to laser light Eye damage may result 2 Never point the laser light at another person 3 Keep the laser equipped unit out of the reach of children 4 Avoid indirect exposure via reflective surfaces such as glass and mirrors ...

Страница 17: ...articular purpose ZippyYum is not liable for incidental indi rect special or consequential damages including without limitation damage to or loss of use of any equipment lost sales or profits or delay or failure to per form this warranty obligation ZippyYum s liability on any claim for damages arising out of in connection with the manufacture sales installation delivery or use of the product shall...

Страница 18: ... Union Directives 1999 5 EC Radio Telecommunications Terminal Equipment R TTE Directive 2014 35 EU Low Voltage LVD Directive 2014 30 EU Electromagnetic Compatibility EMC Directive 2011 65 EU EU Restriction of Hazardous Substances RoHS Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE Directive ACME Australia Standards AS NZS 4268 2012 A1 2013 EN 61000 6 1 2007 EN 61000 6 3 2007 A...

Страница 19: ...19 FABRICATED FOOD SERVICE EQUIPMENT NSF ANSI 2 SA44549 INFRARED THERMOMETER E481655 Industry Canada Industrie Canada IC 21861 THB4002 RCM Cert No POC16104019 FCC ID 2AE6ATHB4002 ...

Страница 20: ...CC Rules These limits are de signed to provide reasonable protection against harmful interference in a residen tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular in...

Страница 21: ...ng two conditions 1 this device may not cause inter ference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et ...

Страница 22: ...22 ZippyYum LLC 275 Centennial Way 105 Tustin CA 92780 Phone 1 888 636 7557 Fax 1 866 434 0883 www zippyyum com www mangoe com ...

Отзывы: