background image

Installation Guide:

for the Warmup 

Tempo

 Digital Programmable Thermostat

Part of the Element Series

 Introduction

The 

Tempo

 thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup 

underfloor heating system. The thermostat is designed to receive temperature input signals from the following sensors:

1.  Air sensor located inside the thermostat

2.  Floor sensor installed in the floor to be heated (see Warmup heater instructions for details)

The thermostat is not a safety device and should only be used with Warmup heating products. In order to avoid damaging 

your flooring the correct floor type must be selected during the thermostat programming process.

Electrical Specification

:

• 

Supply voltage: 230V +/-15% at 50Hz

• 

Thermostat is not designed for use with intermittent power supply.

• 

Maximum Switch Load:  16A resistive

• 

Insulation Class : II 

• 

Housing : IP20

• 

Sensor NTC : 10K @ 25°C

• 

Standards:  EN60730-1 & EN60730-2-9

• 

Meets LVD and EMC directives for safety and electromagnetic compatibility

WARNING – Important safety note

This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always 

isolate the power supply before attempting to install or repair the 

Tempo

 thermostat. The thermostat should not be put into 

operation unless you are certain that the entire heating installation complies with current general safety requirements for 

electrical installations. Electrical installation must be in accordance with the latest IEE Wiring Regulations and appropriate 

Statutory Regulations.

The thermostat should be installed inside a single gang electrical wall box that is at least 32mm deep. For optimal 

performance, the thermostat should be located in an area with good ventilation. It should not be installed beside a drafty 

window/door, in direct sunlight or above another heat generating device (e.g. Radiator or TV).

The thermostat is designed for operation between 0°C and 50°C with relative humidity less than 80%.

 Location and installation of floor sensor

The optimum location of the floor sensor is described in each Warmup heater installation manual. Refer to that manual when 

selecting floor sensor location.

Warmup recommend the use of conduit when installing the floor sensor. The conduit will protect the sensor and will allow 

easier repair of the sensor in the case of sensor damage after flooring has been laid.

 Installation:

Separate the front housing of thermostat from the wall module:

1.  Unscrew both closing screws (bottom of thermostat) until they will not turn any further.

2.  Release front housing by gripping the lower half of outer frame and pulling outwards 

then upwards.

3.  Place front housing somewhere safe.

4.  Run all wires to the wall box. Check to ensure that you have included the following:

• 

Power (Live and Neutral)

• 

Heater (Live and Neutral)

• 

Floor sensor

• 

Fil pilote (France only)

5.  Pull wires through the wall box and complete terminal wiring. 

IMPORTANT:

 Ensure that multi strand wires are fully inserted into the terminal and secured 

tightly. 

Any loose strands should be trimmed as they could cause a short-circuit.

If connecting more than two heaters, an electrical junction box will be required.

 

Thermostat location 

1

2

3

4

ELT-01-XX-01 - Installation guide V1.1 © Warmup plc - 2014 

Отзывы: