Abbreviating commands
: Abbreviated commands are identified with boldface letters. Letters not printed in boldface can be omitted. Example: “
OU
TPUT ON” = “OU ON”
As a rule, letters can be entered in upper or lower case.
Stringing commands together
: Several commands is a single data string must be separated by semicolons (;). Example: “USET 12; ISET 8.5; OUTPUT ON”
Formats for numeric parameters:
m,
n:
Whole number (integer);
w:
Whole number, fixed or floating decimal point number with or without exponent. Examples: “12.5”, “0012.5”, “1.25E1”, “+1.25 e+01”
*
/15 or /1700, respectively as from firmware version 004
Devise-Specific Settings
ADJ
UST
(CAL)
txt(,w)
Balancing/calibration function
UOFF / UFS / IOFF / IFS / (EXIT), 0
w
respective balancing limit.
The specified order for the procedure must be adhered to!
“EXIT”
UNCAL, abort with error message
—
X
X
ANA
LOG_IN txt1,txt2
Connection of analog control inputs U(Uext), U(Iext)
OFF / ON / SSET
OFF
X
X
C_D
YN
txt
Setting for current regulating dynamics
R / L
R
X
X
DI
SPLAY
txt1,txt2
Digital display function switching
txt1: ON / OFF / UO /US / PS
txt2: ON / OFF / IO / IS / PO
UO
IO
X
X
FS
ET
txt
Sequence function parameter
CLR / NF / RU / RI / SOFF / S_ON / AUOF / AUON / AUSS / AIOF /
AION / AISS / R01 ... R12/15* / S01 ... S12/15*
CLR
X
X
IL_H
(
ILI
M)
w
Upper limit value for current setting
Iset
w
Inom [A]
Inom
X
X
IL_L
w
Lower limit value for current setting
0
w
Iset [A]
0
X
X
IS
ET
w
Current setpoint [A]
IL_L
w
IL_H [A]
0
X
X
MEAS_LP
F
txt
Low-pass filter for measured value acquisition
1 / 2 / 3 / 4
3
X
X
MI
NMAX
txt
Min-max storage for measured U and I values
OFF / ON / RST
“ON”
enable tolerance band function for CRB.0/1, ERC.0/1, SIGx_OUT
OFF
X
X
OC_D
ELAY
w
Overcurrent protection triggering delay
0.000
w
65.535 [s]
0
X
X
OCP
txt
Overcurrent protection
OFF / ON / R01
R12/15*
OFF
X
X
OCS
ET
w
Overcurrent protection trigger value
OCSETmin (3) [A]
w
OCSETmax (80 A) [A]
80 A
X
X
OU
TPUT
txt
Switch power output on and off
OFF/ ON
OFF
X
X
OV_D
ELAY
w
Overvoltage protection triggering delay
0.000
w
65.535 [s]
0
X
X
OVP
txt
Overvoltage protection
OFF / ON / R01
R12/15*
ON
X
X
OVS
ET
w
Overvoltage protection trigger value
3 [V]
w
OVSETmax (80 V) [V]
80 V
X
X
POW
ER_ON txt
Response after power on
RST / SBY / RCL / R01
R12/15*
RST
X
X
PS
ET
w
Power setpoint [W]
0
w
Pnom (1500, 3000, 4500) [W] (PSET = PNOM)
P-REG. OFF) Pnom
X
X
RE
PETITION n(,i)
Number of repetitions for sequence function
0
n
255; 0 means continuous repetition.
i is an optional parameter for the setup memory location (1 through
12/15), which should be written directly with REPETITION.
0
X
X
SEQ
UENCE
txt(,n)
SEQUENCE control command
OFF / GO / HOLD / CONT(,n) / STRT / STEP (,n) / BSTP / STOP / ESC
n is an optional parameter from start address to stop address
—
X
X
SIG
123
txt1,txt2,txt3
Analog interface signal outputs
OFF / ON / OUT / MODE / SEQ / SSET / U_LO / U_HI / I_LO / I_HI
OFF
X
X
SINK
txt
Sink function on/off
OFF / ON
ON
X
X
SM_L
OAD
n
Load sequence memory location
USET,ISET,TSET,FSET
1
n
1536/1700* —
X
X
SM_S
TORE
n
Write current USET,ISET,TSET,FSET to sequence
memory location
1
n
1536/1700*
n = 0: clear contents from start to stop address
—
X
X
SS
ET
txt
Command for an assigned switching function
OFF / ON
OFF
X
X
STA
RT_STOP m,n(,i)
Start and stop address
1
n1
n2
1536/1700*
i is an optional parameter for the setup memory location (1 through
12/15), which should be written directly with START_STOP.
1.1
X
X
STO
RE
n,w1,w2,w3,txt Transfer parameters directly to memory
1
n
1536/1700* , memory location address
0
w1
Unom [V]
0
w2
Inom [V]
0
w3
65.535 [s], 0 means Tdef
txt, see “FSET”
—
X
X
T_M
ODE
txt1,txt2
Function selection for trigger inputs
OFF / OUT / SQS / SEQ(,n) / LLO / MIN (,n) / AIX / AIU / AII
OFF
X
X
TD
EF
w(,i)
Default time rate for SEQUENCE function
0.001
w
65.535 [s]
i is an optional parameter for the setup memory location (1 through
12/15*), which should be written directly with TDEF.
0.001
X
X
TIME
DATE
txt
Set system clock (RTC)
yyyy-mm-ddThh:mm:ss
unv
X
X
TS
ET
w
Memory location-specific dwell time for sequence
function
0.000 = Tdef, 0.001
w
65.535 [s]
0.000
X
X
UI
_C_SET
w1,w2,w3,w4
Reference values for Uout/Iout, tolerance band
function
w1, w2:
0
w1 < w2
Unom [V]
w3, w4:
0
w3 < w4
Inom [A]
0,Unom,
0, Inom
X
X
UL_H
(
ULI
M) w
Upper limit value for voltage setting
Uset
w
Unom
[V]
Unom
X
X
UL_L
w
Lower limit value for voltage setting
0
w
Uset [V]
0
X
X
US
ET
w
Voltage setpoint [V]
UL_L
w
UL_H [V]
0
X
X
WA
IT
w
Additional waiting time
0.001
w
65.535 [s]
—
X
Setting
Command
Parameter
Meaning
Value Range / Selection
De
fa
ul
t
Set
tin
g Afte
r
RE
SET
*RS
T
Manual
Re
m
o
te
Содержание P1500
Страница 68: ...68 GMC I Messtechnik GmbH ...
Страница 71: ...GMC I Messtechnik GmbH 71 ...