Safety Precautions
• Make certain that the measurement cables are in flawless
condition, e.g. no damage to insulation, no interruptions in
cables or plugs etc.
• Device functions may not be executed in electrical circuits with
corona discharge (high-voltage).
• Special care is required when measurements are made in HF
electrical circuits. Dangerous pulsating voltages may be
present.
• Measurements under moist ambient conditions are not
permitted.
• Be absolutely certain that the measuring ranges are not
overloaded beyond their allowable capacities. Limit values are
included in section 9, “Technical Data”, in the table entitled
“Measuring Functions and Measuring Ranges” in the
“Overload Capacity” column.
• The multimeter may only be operated with installed batteries or
rechargeable batteries. Dangerous currents and voltages are
otherwise not indicated, and the instrument may be damaged.
• The instrument may not be operated if the fuse cover or the
battery compartment lid has been removed, or if its housing is
open.
• The input for the current measuring range is equipped with a
fuse link. Maximum permissible voltage for the measuring
circuit (= rated voltage of the fuse) is 300 V AC/DC. Use speci-
fied fuses only (see page 73)! The fuse must have a
breaking capacity of at least 1,5 kA
.
Special Safety Precautions for the Calibrator
•
If necessary, use the multimeter section of the instrument to
make sure that no dangerous contact voltages are present in
the signal circuits to which the instrument is to be connected.
•
In order to prevent damage to the instrument, observe the
maximum
allowable voltage and current values indicated at
the jacks.
With the exception of the resistance simulation and mA SINK
operating modes, the connected signal circuits should not
feed any voltage or current back to the calibrator.
In order to avoid damage to the instrument when interference
voltages are applied (within allowable limit values), the mA
SINK and mA SOURCE circuits are equipped with an fuse,
which makes this circuit highly resistive in the event that
excessive current should occur in case of a fault for the
duration of overloading.
Содержание METRACAL MC
Страница 1: ...METRACAL MC Multimeter Calibrator Operating Instructions 3 349 566 03 7 2 15 ...
Страница 5: ...GMC I Messtechnik GmbH 5 Contact Persons ...
Страница 25: ...GMC I Messtechnik GmbH 25 Control Functions ...
Страница 65: ...GMC I Messtechnik GmbH 65 Device and Measuring Parameters ...
Страница 75: ...GMC I Messtechnik GmbH 75 Technical Data ...