9
Gossen Metrawatt GmbH
METRACABLE TDR PRO
4.4
Instrument Menus
The instrument has two menus: the main menu with basic settings and the TDR menu with
specific settings for measurements.
•
•
Main Menu Overview
Press and hold the
ESC
key in order to open the main menu. Use the scroll keys to navigate
within the menu, and to make selections and entries. Press the
SEL
key in order to acknowl-
edge a selection. Click
TDR Measurement
in order to return to the TDR trace.
TDR measurement
Exit menu / return to measurement
Velocity factor
VF value
The material-dependent velocity of propagation of the signal within the
cable is taken into consideration by means of the VF value. It must be
selected individually for each respective cable so that distance can be
calculated correctly.
Cable type
Access to the cable database and selection of the cable type (including
VF value entries)
(max. 32 entries)
(
18)
Data transmission
Activate Bluetooth for data transmission to the PC (METRACABLE
MANAGER
18).
Settings
Language
German, English, French
Unit of measure
Meters (m) or feet (ft) in combination with velocity
factor VF or half of velocity factor VF/2
Battery type
Battery or rechargeable battery
(depending on which is used
30)
Illumination
Display illumination time after last entry
0 … x sec. (0 = continuously on)
Shutdown
Auto-shutdown of the instrument after last entry
0 … x min. (0 = continuously on)
Contrast
-20 … +50 (default: 20)
Program update
Start the update process
Time
Time of day in 24-hour format
Date
Date in format DD/MM/YY