OM−06078
PA SERIES
PAGE B − 4
INSTALLATION
If there is a liquid flow from an open pipe into the
sump, the flow should be kept away from the suc-
tion inlet because the inflow will carry air down into
the sump, and air entering the suction line will re-
duce pump efficiency.
If it is necessary to position inflow close to the suc-
tion inlet, install a baffle between the inflow and the
suction inlet at a distance 1-1/2 times the diameter
of the suction pipe. The baffle will allow entrained
air to escape from the liquid before it is drawn into
the suction inlet.
If two suction lines are installed in a single sump,
the flow paths may interact, reducing the efficiency
of one or both pumps. To avoid this, position the
suction inlets so that they are separated by a dis-
tance equal to at least 3 times the diameter of the
suction pipe.
Suction Line Positioning
The depth of submergence of the suction line is
critical to
efficient
pump operation. Figure 2
shows recommended minimum submergence vs.
velocity.
Although not recommended, the vacuum assisted
priming feature allows the pump to be operated
temporarily in a slurping" application with varying
water levels.
NOTE
The pipe submergence required may be reduced
by installing a standard pipe increaser fitting at the
end of the suction line. The larger opening size will
reduce the inlet velocity. Calculate the required
submergence using the following formula based
on the increased opening size (area or diameter).
Figure 2. Recommended Minimum Suction Line Submergence vs. Velocity
Содержание PA4C60-4045H
Страница 22: ...OM 06078 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE SECTION DRAWING Figure 1 Pump Model PA4C60 4045H...
Страница 24: ...OM 06078 PA SERIES MAINTENANCE REPAIR PAGE E 4 SECTION DRAWING Figure 2 46143 064 Power Unit Kit...
Страница 26: ...OM 06078 PA SERIES MAINTENANCE REPAIR PAGE E 6 SECTION DRAWING Figure 3 PA4C60 SAE 4 10 Pump End Assembly...
Страница 28: ...OM 06078 PA SERIES MAINTENANCE REPAIR PAGE E 8 SECTION DRAWING Figure 4 Pump Assembly...