OM-06674
PAH SERIES
OPERATION
PAGE C - 1
OPERATION - SECTION C
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and
decals attached to the pump.
This pump is designed to handle liquids
containing large entrained solids and
slurries. Do not attempt to pump vola
tile, corrosive, or flammable liquids
which may damage the pump or endan
ger personnel as a result of pump fail
ure.
Pump speed and operating condition
points must be within the continuous per
formance range shown on the perfor
mance curve in Section E on page E-1.
PRIMING
Install the pump and piping as described in
IN
STALLATION
. Make sure that the piping connec
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri
cated (see
LUBRICATION
in
MAINTENANCE
AND REPAIR
).
The pump will begin to prime upon startup. The air
in the suction line will be discharged from the educ
tor discharge line. Complete priming is indicated
by a positive discharge pressure reading.
If full priming is not achieved, the discharge check
valve may be malfunctioning. If this occurs, shut
down the pump and consult
Maintenance and
Repair,
Section E
for further details.
STARTING
Consult the operations manual furnished with the
power source.
Rotation
The correct direction of pump rotation is counter
clockwise when facing the impeller. The pump
could be damaged and performance adversely af
fected by incorrect rotation. If pump performance
is not within the specified limits (see the curve on
page E‐1), check the direction of power source ro
tation before further troubleshooting.
If an electric motor is used to drive the pump, re
move the coupling or otherwise disconnect the
pump from the motor before checking motor rota
tion. Operate the motor independently while ob
serving the direction of the motor shaft or cooling
fan.
If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction.
Priming
The pump will begin to prime upon startup. The air
in the suction line will be discharged from the educ
tor discharge line. Complete priming is indicated
by a positive discharge pressure reading.
If full priming is not achieved, the discharge check
valve may be malfunctioning. If this occurs, shut
down the pump and consult the separate
Mainte
nance and Repair
manual
for further details.
OPERATION
Leakage
Once the pump is fully primed, no leakage should
be visible at pump mating surfaces, or at pump
connections or fittings. Keep all line connections
and fittings tight to maintain maximum pump effi
ciency.
Содержание PRIME AIRE PLUS PA10A60C-B
Страница 17: ......
Страница 23: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PAH10A60C B ...
Страница 25: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46133 503 Pump End Assembly ...
Страница 27: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 44163 565 Repair Rotating Assembly ...
Страница 33: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 12 ILLUSTRATION Figure 7 Air Compressor Wiring Schematic ...