OM-06674
PAH SERIES
OPERATION
PAGE C - 3
PERIODIC CHECKS
Seal Cavity And Bearing Lubrication
Both the seal and bearing cavities were fully lubri
cated at the factory. Check the lubrication levels
before startup, and regularly thereafter as indi
cated in Section E,
Maintenance and Repair
.
When lubrication is required, use
only
SAE No. 30
non‐detergent oil.
Bearing Temperature Check
Bearings normally run at higher than ambient tem
peratures because of heat generated by friction.
Temperatures up to 160
F (71
C) are considered
normal for bearings, and they can operate safely to
at least 180
F (82
C).
Checking bearing temperatures by hand is inaccu
rate. Bearing temperatures can be measured ac
curately by placing a contact‐type thermometer
against the housing. Record this temperature for
future reference.
A sudden increase in bearing temperatures is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor
rect level (see
LUBRICATION
in Section E,
Main
tenance and Repair
). Bearing overheating can
also be caused by shaft misalignment and/or ex
cessive vibration.
When pumps are first started, the bearings may
seem to run at temperatures above normal. Con
tinued operation should bring the temperatures
down to normal levels.
Air Compressor
The air compressor was lubricated for test at the
factory. However,
always
check the lubrication lev
el before startup.
Consult the manual accompanying the air com
pressor and preform all duties and checks as indi
cated.
COLD WEATHER PRESERVATION
In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any
remaining liquid that could freeze the pump rotat
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.
Содержание PRIME AIRE PLUS PA10A60C-B
Страница 17: ......
Страница 23: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PAH10A60C B ...
Страница 25: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46133 503 Pump End Assembly ...
Страница 27: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 44163 565 Repair Rotating Assembly ...
Страница 33: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 12 ILLUSTRATION Figure 7 Air Compressor Wiring Schematic ...