![GORMAN-RUPP PUMPS PRIME AIRE PLUS PA10A60C-B Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/gorman-rupp-pumps/prime-aire-plus-pa10a60c-b/prime-aire-plus-pa10a60c-b_installation-operation-and-maintenance-manual-with-parts-list_2246905012.webp)
OM-06674
PAH SERIES
PAGE B - 5
INSTALLATION
from excessive shock pressure and reverse rota
tion when it is stopped.
If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.
ALIGNMENT
This pump is designed for direct coupled
drive only. Use of a V‐belt drive will dam
age the pump and void the pump warranty.
The alignment of the pump and its power source is
critical for trouble‐free mechanical operation. The
driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera
tion.
NOTE
Check
Rotation
, Section C, before final alignment
of the pump.
When mounted at the Gorman‐Rupp factory, driver
and pump are aligned before shipment. Misalign
ment will occur in transit and handling. Pumps
must
be checked and realigned before operation.
Before checking alignment, tighten the foundation
bolts. The pump casing feet and/or pedestal feet,
and the driver mounting bolts should also be tightly
secured.
When checking alignment, disconnect
the power source to ensure that the
pump will remain inoperative.
Adjusting the alignment in one direction
may alter the alignment in another direc
tion. check each procedure after altering
alignment.
Coupled Drives
When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer's service literature.
Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90
.
The coupling is in alignment when the hub ends
are the same distance apart at all points (see Fig
ure 2).
Figure 2. Aligning Spider‐Type Couplings
Figure 3. Aligning Non‐Spider Type Couplings
Align non‐spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90
. The coupling is in alignment when the
hubs are the same distance apart at all points (see
Figure 3).
Содержание PRIME AIRE PLUS PA10A60C-B
Страница 17: ......
Страница 23: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PAH10A60C B ...
Страница 25: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46133 503 Pump End Assembly ...
Страница 27: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 44163 565 Repair Rotating Assembly ...
Страница 33: ...OM 06674 PAH SERIES MAINTENANCE REPAIR PAGE E 12 ILLUSTRATION Figure 7 Air Compressor Wiring Schematic ...