8
AIR CONDITIONER FEATURES
Electronic control operating instructions
Before you begin, thoroughly familiarize yourself with the control panel and remote
controller and all its functions, then follow the symbol for the functions you desire.
The unit can be controlled by the unit control panel alone or with the remote
controller.
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Operation panel of the air conditioner
NOTE: On some models SLEEP button is instead of ECO button.
1. MODE select button
Selects the appropriate operating mode. Each time you press the button, a
mode is selected in a sequence that goes from COOL, DRY, FAN and
(cooling only models without). The mode indicator light illuminates under the
different mode settings.
2. Up (+) and down (-) button
Used to adjust (increasing/decreasing) temperature settings (1°C / 2°F
increments) in a range of 17°C (62°F) to 30°C (88°F).
NOTE: The control is capable of displaying temperature in degrees
Fahrenheit or degrees Celsius. To convert from one to the other, press and
hold the Up and Down buttons at the same time, for 3 seconds.
3. Power button
Power switch on/off.
4. LED display
Shows the set temperature in "°C" or "°F" and the Auto-timer settings. While
on DRY and FAN modes, it shows the room temperature.
Error codes and protection code:
•
E1 – Room temperature sensor error - Unplug the unit and plug it back
in. If error repeats, call for service.
•
E2 – Evaporator temperature sensor error - Unplug the unit and plug
it back in. If error repeats, call for service.
•
E4 – Display panel communication error - Unplug the unit and plug it
back in. If error repeats, call for service.
•
P1 – Bottom tray is full - Connect the drain hose and drain the
collected water away. If protection error repeats, call for service.
Power indicator
Timer indicator