Dishwasher must be level for proper dish rack operation and wash performance.
Place a spirit level on door and rack track inside the tub as shown to check that the
dishwasher is level.
level the dishwasher by adjusting the three levelling legs individually.
When level the dishwasher, please pay attention not to let the dishwasher tip over.
1
2
3
Illustration of feet adjustment
Ǐ
ǐ
Figure 8
NOTE:
The maximum adjustment
height of the feet is 50 mm.
This appliance must be earthed. In the event
of a malfunction or breakdown, earthing will
reduce the risk of electric shock by providing a
path o f least resistance for the electric current.
This appliance is equip ped with a cord having an
equipment-earthin g co nductor and an earthing
plug. The plug must be plugged into an appropriate
outlet that is in stalled and earthed in accordance
with all local standards and requirements.
I mpr oper connecti on of th e equ ipment -
earthing conductor can re sul t i n th e risk
of an el ectric shock. C he ck wi th a qualified
electri ci an or service represe ntativ e if you
are i n doubt whether the app li an ce is properly
earthed. Do not mo dify t he plug p rovided w ith
t he appliance; If it is n ot f it for the outlet .
H ave a proper ou tlet in stalled b y a qual ifi ed
electri ci an.
Ensure the voltage and fr equency of the power be ing cor respond s to
those on the rating pl ate. Only insert the plug into an electrical so cket which is earthed
properly. If the electrical socket to which the applianc e must be conne cted is not
appropriate for the pl ug , replace the socket, rather th an using a adaptors or t he like a s
they coul d ca use overhea ting and burns.
Plea se look at the ra ting label to know the rat ing volta ge and connect the dishwash er to the app ropriate power s upp ly.
Use the required fuse 10 amp, time delay fuse or circuit breaker rec ommended and provide separate circuit serving
only this appliance.
For personal safety:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANC E.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR R EMOVE THE EARTHING
CONNECTION FROM THE POWER CORD.
Check level si de to side
Spirit level
Chec k level Front to Back
1.Pull The safety supply hoses completely out from storage compartment located at rear of dishwasher.
2.Tighter the screws of the safety supply hose to the faucet with thread 3/4inch.
3.Turn water fully on before starting the dishwasher.
The appliance mus t be connected to the water mains using new hose-sets. The old hose-sets
should not be reused.
Wate r pressure must b e between 0,04 MPa and 1 MPa. If the pressu re is below the minimum
consult our Servic e Department for advice.
Содержание GV63315UK
Страница 1: ...GV63315UK...