GB 27
Additional requirements for the integration (flush installation) of the hob
(HI7271MSI, HI8271SI and HI9271SI)
• The hob can only be integrated above a single cupboard at least
800/900 mm wide (see illustration).
• Once it has been integrated, the hob must remain accessible from
underneath for service purposes.
• If a drawer or oven is built in under the hob it must be easily
removable.• These hobs are particularly suitable for integration in
stone or tiled worktops.
• When integrating the hob it should only be kitted along the side
of the glass top and not at the bottom. This is to ensure that the
glass top itself remains accessible should it need to be replaced.
To do this, apply a layer of tape, such as masking tape, to the inlay
surface.
• Report any transit damage before sealing the hob. Any damages
reported afterwards will be deemed a result of it being built in.• The
guarantee does not cover damages resulting from the hob being
built in.
• The guarantee does not cover water damage or any other damage
to the worktop the hob is built into.
• Prior to any service call, all interior parts of the cupboard the hob is
built into, such as drawer constructions, shelves, racks and runners,
are to be removed.• The service department is responsible for the
repair and service of the hob only. You should contact your kitchen
specialist about the re-integration (flush installation) of the hob.
• The kit used to seal the edges of the glass top must be resistant to
temperatures of at least 160 °C.
• To prevent discolouration of the natural stone, use a specially
developed sealant between the glass and natural stone.
min. 800 mm
for HI7271SI/HI8271SI
min. 900 mm
for HI9271SI
Tape
Kit