The appliance may be used by children older than 8 years old, elderly
persons and persons with physical, sensory or mental disabilities or lacking
experience and knowledge, if they are under supervision or taught about
safe use of the appliance and if they are aware of the potential dangers.
Children should not play with the appliance.
Children should not clean or perform maintenance on the appliance without
supervision.
Installation should be carried out in accordance with the valid regulations
and according to the instructions of the manufacturer and by qualified staff.
In a closed, pressurised system of installation, it is obligatory to install a safety
valve on the inlet pipe with a rated pressure of 0.6 MPa (6 bar), 0.9 MPa
(9 bar) or 1.0 MPa (10 bar) (see the label), which prevents the elevation of
pressure in the boiler by more than 0.1 MPa (1 bar) above the rated pressure.
Water may drip from the outlet opening of the safety valve, so the outlet
opening should be set to atmospheric pressure.
The outlet of the safety valve should be installed facing downwards and in a
non-freezing area.
To ensure proper functioning of the safety valve, the user should perform
regular controls to remove limescale and make sure the safety valve is not
blocked.
Do not install a stop valve between the water heater and the safety valve,
because it will impair the pressure protection of the heater!
Before connecting it to the power supply, the water heater must be filled
with water!
The heater is equipped with an additional thermal cut-off for protection
in case of failure of the operating thermostat. In this case, however, the
temperature of the water in the heater can reach up to 130 °C according to
the safety standards. During the water supply installation, the possibility of
temperature overloads should be taken into account.
If the heater is to be disconnected from the power supply, please drain any
water from the heater to prevent freezing.
Water from the heater that is installed vertically on the wall can be drained
through the heater's inlet pipe. For this purpose it is advisable to install a T-
element with an outlet valve between the inlet pipe and safety valve.
A heater installed horizontally on a wall can only be emptied by an
authorised service provider.
Please do not try to fix any defects of the water heater on your own. Call
the nearest authorised service provider.