EN 17
CONNECTING TO THE POWER MAINS
The electric range is a heat consumer, the
installation
and
location
of
which
must
correspond with local standards in force.
A device disconnecting the appliance from mains,
whose off contacts of all poles are in a minimum
distance of 3 mm, must be built in the stable
electrical energy distribution before the appliance.
Solely an authorised, skilled person may install the
range. The authorised person is obliged to set the
range cooking plate in horizontal position, to connect
it to the mains and to check up on its duty.
Installation of the range must be confirmed in the
certificate of warranty.
There is the recommended three-phase connection
of the range with the aid of an H05VV-F5G-1,5 type
connecting cord (previously CGLG 5Cx1,5), (circuit
breaker 3x16 A).
For single-phase connection use an H05VV-F3G-4
(previously GGLG 3Cx4), (circuit breaker 32 - 40 A
to the type).
It is necessary to brace the conductor ends with
pressed terminals against fraying.
After bracing the conductor ends beneath the
terminal board screw heads place a cord in the
terminal board and secure it by a clip against
tearing. Eventually close the terminal board cover.
CLAMP PROTECTION
The clamps should be protected by a clamp cover,
see additional equipment. Electric shock danger.
IMPORTANT NOTICE
At any electric range disassembly or assembly
besides its current use it is necessary to disconnect
the appliance from mains and to keep it out of
service.
In installation of the appliance, it is necessary to
do in the light of its duty chiefly the following:
Verification
of
the
correctness
of
mains
connection.
A check on the duty of heaters, control and
governing elements.
Presentation to the client of all functions of the
appliance and familiarisation with its service and
maintenance.
NOTICE
The electric range is a Class I appliance according
to the electric current injury prevention degree and
must be interconnected with the mains protective
conductor.