background image

15

5-2

 

Explanation of the required components

Compressor 

Most factories are equipped with a compressor. When purchasing a new one, we recommend 
an oilless compressor. 

Air Dryer 

The Air Dryer removes moisture from the air. The Nitrogen separation membrane inside 
the station is adversely affected by moisture. Performance will decrease if moisture is 
not removed from the air. A temperature up to +3°C above the dew point temperature is 
acceptable. 

Air Filter or Mist Separator (Recommended: SMC Corporation AF20-01/
AFM20-01) *

The Air Filter removes large particles or highly concentrated oil droplets from the air. The 
Micro Mist Separator also performs this function. However, compared to the Air Filter it only 
filters smaller particles and low concentration oil droplets from the air, so it is easily clogged. 
The Air Filter could be considered as a pre-filter to protect the Micro Mist Separator. 

Micro Mist Separator (Recommended: see below) 

 

The Micro Mist Separator removes the tiny particles and oil droplets in the air that could not 
be removed by the Air Filter/Mist Separator. Even minute particles that enter the N

2

 Station 

can cause problems. The Micro Mist Separator plays an important role in protecting the N2 
Station. 

Regulator (Recommended: see below) 

The maximum input air pressure is 0.7MPa. The Regulator controls the air pressure going into 
the N

2

 Station so that it is under 0.7MPa. If the input air pressure is already less than 0.7MPa, 

then the Regulator is not required. However, to protect the 

NC-100R 

from sudden air pressure surges we strongly recommend installing the 
Regulator. 

Micro Mist Separator Regulator (Modular) 

(Recommended: AWD20-01E, Square embedded type pressure 
gauge attached) 

This is made up of a Regulator and a Micro Mist Separator. 
Micro Mist Separator and Regulator may be purchased separately, or 
you may purchase the combined modular unit. 

* For connections, a 1/8 standard is recommended.

Содержание NC-100R

Страница 1: ...N2 N2 Station NC 100R NC 100R See English version from P 9...

Страница 2: ...L min 0 5 4 0 L min 60 185 L 118 W 112 H 2Kg N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATIO...

Страница 3: ...3 4 4 1 N2 1 10 N2 4 2 OFF 2 80 0 01mg m3 0 01 m RX 802ASPH 0 5 1 5 L min 0 7MPa N2 99 9 99 7 99 2 98 3 N2 L min 0 5 1 0 1 5 2 0 N2 RX 802ASPH 3 N2 4 N2...

Страница 4: ...4 4 2 NC 1 00R SER NO AIR IN MAX 0 7MPA N2 4mm N2 0 5 4 0 L min N2 N2 ON OFF 0 7MPa 6mm...

Страница 5: ...5 N2 0 7MPa 7kgf c 0 7MPa N2 NC 100R 5...

Страница 6: ...6 5 1 NC 100R RX 802ASPH 1MPa 0 3 0 7MPa NC 100R N2 NC 100R 6mm RX 802ASPH 2...

Страница 7: ...7 5 2 N2 N2 3 SMC AF20 01 AFM20 01 N2 N2 N2 0 7MPa N2 0 7MPa 0 7MPa SMC AWD20 01E 1 1 8...

Страница 8: ...8 6 7 N2 1 1 1 1 No NC 6 2m B1072YG00 N2 N2 5 1 NC 100R 1 0L min 1 8 2...

Страница 9: ...structions and safety precautions in this manual and on the product and use the N2 Station properly and only for what it is intended you will enjoy years of safe reliable service Operation Manual WARN...

Страница 10: ...Input Air Temperature 5 C 50 C Nitrogen Generation Density More than 99 5 0 7MPa 0 5L min Recommended Nitrogen Generation Flow Rate 1 0L min Flow Meter 0 5 4 0 L min Max Environmental Temp 60 C Dimens...

Страница 11: ...than 0 01mg m3 Particles Less than 0 01 m RX 802ASPH 0 5 1 5 L min When the air pressure supplied is 0 7MPa Nitrogen Density 99 9 99 7 99 2 98 3 Nitrogen Flow rate L min 0 5 1 0 1 5 2 0 Requirements f...

Страница 12: ...4mm Nitrogen Flow Meter Measurement Range 0 5 4 0 L min Nitrogen Flow Regulation Turn to left Increase flow Turn to right Decrease flow Nitrogen Output Valve Turn to left ON Turn to right OFF Please...

Страница 13: ...disconnect or even explode Compressed air supplied by the compressor can contain water oil or dust Make sure these elements do not enter the unit by using appropriate filters Please note that Nitrogen...

Страница 14: ...mm diameter tube included with the station It can be attached Connect to Compressed Air Input on the back of the unit Temperature Controlled Lead free applicable Soldering Station The tube from the ha...

Страница 15: ...to protect the Micro Mist Separator Micro Mist Separator Recommended see below The Micro Mist Separator removes the tiny particles and oil droplets in the air that could not be removed by the Air Filt...

Страница 16: ...r nearest distributor NOTE The Nitrogen Gas Separation Membrane inside this device is not available as a replacement part Please return the unit to your distributor to have this repaired At the follow...

Отзывы: