4-2 各部の名称

NC-100R

SER NO

AIR IN

MAX. 0.7MPA

正面側

背面側

N2 ガス排出口

適合チューブ
外径 φ4mm 

N2 ガス
フローメーター 

測定流量レンジ 
0.5 - 4.0 L/min 

N2 ガス
流量調整ツマミ

左回し(+方向 )

:増加 

右回し(−方向 )

:減少 

N2 ガス排出
バルブ 

左に回す

:ON 

右に回す

:OFF

※ツマミは必ず左右
どちらかに回しきって
下さい。

銘板シール 

圧縮空気入力口

 (最大 0.7MPa)
適合チューブ
外径φ6mm

Содержание NC-100R

Страница 1: ...N2 N2 Station NC 100R NC 100R See English version from P 9...

Страница 2: ...L min 0 5 4 0 L min 60 185 L 118 W 112 H 2Kg N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATIO...

Страница 3: ...3 4 4 1 N2 1 10 N2 4 2 OFF 2 80 0 01mg m3 0 01 m RX 802ASPH 0 5 1 5 L min 0 7MPa N2 99 9 99 7 99 2 98 3 N2 L min 0 5 1 0 1 5 2 0 N2 RX 802ASPH 3 N2 4 N2...

Страница 4: ...4 4 2 NC 1 00R SER NO AIR IN MAX 0 7MPA N2 4mm N2 0 5 4 0 L min N2 N2 ON OFF 0 7MPa 6mm...

Страница 5: ...5 N2 0 7MPa 7kgf c 0 7MPa N2 NC 100R 5...

Страница 6: ...6 5 1 NC 100R RX 802ASPH 1MPa 0 3 0 7MPa NC 100R N2 NC 100R 6mm RX 802ASPH 2...

Страница 7: ...7 5 2 N2 N2 3 SMC AF20 01 AFM20 01 N2 N2 N2 0 7MPa N2 0 7MPa 0 7MPa SMC AWD20 01E 1 1 8...

Страница 8: ...8 6 7 N2 1 1 1 1 No NC 6 2m B1072YG00 N2 N2 5 1 NC 100R 1 0L min 1 8 2...

Страница 9: ...structions and safety precautions in this manual and on the product and use the N2 Station properly and only for what it is intended you will enjoy years of safe reliable service Operation Manual WARN...

Страница 10: ...Input Air Temperature 5 C 50 C Nitrogen Generation Density More than 99 5 0 7MPa 0 5L min Recommended Nitrogen Generation Flow Rate 1 0L min Flow Meter 0 5 4 0 L min Max Environmental Temp 60 C Dimens...

Страница 11: ...than 0 01mg m3 Particles Less than 0 01 m RX 802ASPH 0 5 1 5 L min When the air pressure supplied is 0 7MPa Nitrogen Density 99 9 99 7 99 2 98 3 Nitrogen Flow rate L min 0 5 1 0 1 5 2 0 Requirements f...

Страница 12: ...4mm Nitrogen Flow Meter Measurement Range 0 5 4 0 L min Nitrogen Flow Regulation Turn to left Increase flow Turn to right Decrease flow Nitrogen Output Valve Turn to left ON Turn to right OFF Please...

Страница 13: ...disconnect or even explode Compressed air supplied by the compressor can contain water oil or dust Make sure these elements do not enter the unit by using appropriate filters Please note that Nitrogen...

Страница 14: ...mm diameter tube included with the station It can be attached Connect to Compressed Air Input on the back of the unit Temperature Controlled Lead free applicable Soldering Station The tube from the ha...

Страница 15: ...to protect the Micro Mist Separator Micro Mist Separator Recommended see below The Micro Mist Separator removes the tiny particles and oil droplets in the air that could not be removed by the Air Filt...

Страница 16: ...r nearest distributor NOTE The Nitrogen Gas Separation Membrane inside this device is not available as a replacement part Please return the unit to your distributor to have this repaired At the follow...