RC32c and RC16C Operators Manual
Goodwin Electronics
D1011/v1.7 /23/10/03
Page 11
The A display indicates the code number of the event (se list below) and the B display gives the
time stamp of when the event occurred in minutes (displayed as a hexadecimal number).
The batch window displays F to indicate the RECORD mode and the next digit will have a bar that
toggles every minute to indicate that the internal clock is functioning.
CODE NUMBERS
01 Power up.
02 RS232 upload has occurred.
03 RS232 download has occurred.
04 RS232 failed.
05 RUN mode deselected via keyboard RUN key.
06 RUN mode selected via keyboard RUN key.
05, 08
External RUN deselect request from digital input line.
06, 09
External RUN select request from digital input line
0A
External DATUM request from digital input line.
01, 0B
System has had an NMI signal.
0C
Reserved.
The record and incremental time clock can be cleared by rapidly pressing the decimal point key
twice in quick succession.
To view back through the record file press ENTER. Note that the latest record has the lowest
number, ie., 1.
To exit this mode press the COPY key twice in quick succession, or press the MODE key.