BIOSPRAY®-10C 1020
9
Problem
Cause
Solution
Constant ‘hissing’
noise
Damage to spray
gun or coil hose
Check both parts to be
sure where the damage
has occurred. Contact
Goodway Technologies
to acquire the proper
replacement parts.
Regulator frozen
or damaged
Wait for the regulator
to get back to room
temperature, then
continue use. Repair
or replace regulator if
damaged
Spray gun is
sputtering
Debris in nozzle
Packing nut is too
loose, allowing air
to leak
Remove the nozzle and
spray the compressed
air for 15 seconds.
Tighten the packing nut,
located near the trigger
of the spray gun
.
Operating Pressure
24-26 PSI
Working Tank Pressure
800-1000 PSI (Full Tank)
Operating Environmental
Temperature
68°F +/- 20°F (20°C +/- 11°C)
Air Flow
5.4 CFM
Siphon Rate
160 mL/min (5.4oz/min)
Tank Safety Relief
3000 PSI
Regulator Safety Relief
150 PSI
TROUBLESHOOTING
TECHNICAL INFORMATION