SUC TION PRESSU RE

PSIG  

R-22  

R-410A  

50

26

1

52

28

3

54

29

4

56

31

6

58

32

7

60

34

8

62

35

10

64

37

11

66

38

13

68

40

14

70

41

15

72

42

16

74

44

17

76

45

19

78

46

20

80

48

21

85

50

24

90

53

26

95

56

29

100

59

31

110

64

36

120

69

41

130

73

45

140

78

49

150

83

53

160

86

56

170

90

60

SATURATED SUCTION PRESSURE

 TEMPER ATU RE CHART

SATU RATED SUCTION  

TEMPERATURE 

º

F

LIQUID  PRESSURE

PSIG  

R-22  

R-410A  

200

101

70

210

105

73

220

108

76

225

110

78

235

113

80

245

116

83

255

119

85

265

121

88

275

124

90

285

127

92

295

130

95

305

133

97

325

137

101

355

144

108

375

148

112

405

155

118

415

157

119

425

n/a

121

435

n/a

123

445

n/a

125

475

n/a

130

500

n/a

134

525

n/a

138

550

n/a

142

575

n/a

145

600

n/a

149

625

n/a

152

SATURATED LIQUID PR ESSU RE

 TEMPER ATU RE CHART

SATURATED LIQUID 

TEMPERATURE 

º

F

NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Содержание GSZ16

Страница 1: ...lity of the carrier Verify the model number specifications electrical characteristics and accessories are correct prior to installation The distribu tor or manufacturer will not accept claims from dea...

Страница 2: ...r springs can be installed between the con densing unit legs or frame and the roof mounting assembly to reduce noise vibration NOTE These units require special location consideration in areas of heavy...

Страница 3: ...tance Cond Unit Tons Suct Liq Suct Liq Suct Liq 1 1 2 5 8 1 4 3 4 3 8 3 4 3 8 2 5 8 1 4 3 4 3 8 3 4 3 8 2 1 2 5 8 1 4 3 4 3 8 7 8 3 8 3 3 4 3 8 7 8 3 8 1 1 8 3 8 3 1 2 7 8 3 8 1 1 8 3 8 1 1 8 3 8 4 7...

Страница 4: ...ented lines will cause poor performance or compressor damage Do NOT make final refrigerant line connection until plugs are removed from refrigerant tubing NOTE Before brazing verify indoor piston size...

Страница 5: ...ch located near the unit do not install the switch on the unit Refer to the installa tion instructions supplied with the indoor furnace air handler for specific wiring connections and indoor unit conf...

Страница 6: ...f disabling this function is desired move the jumper from DLY to NORM on the defrost control Adequate refrigerant charge for the matching HSVTC evapora tor coil and 15 feet of lineset is supplied with...

Страница 7: ...Charge Adjustment The outdoor temperature must be 60 F or higher Set the room thermostat to COOL fan switch to AUTO and set the tem perature control well below room temperature Purge gauge lines Conne...

Страница 8: ...URATED SUCTION TEMPERATURE F LIQUID PRESSURE PSIG R 22 R 410A 200 101 70 210 105 73 220 108 76 225 110 78 235 113 80 245 116 83 255 119 85 265 121 88 275 124 90 285 127 92 295 130 95 305 133 97 325 13...

Страница 9: ...nit and refrigerant tubing sizes These adjustments should only be performed by qualified service personnel AdvancedAdjustmentRecommendations SUPERHEATFORMULA SUCTIONLINETEMPERA TURE SATURATEDSUCTIONTE...

Страница 10: ...t with Voltmeter Low Voltage Test Voltage Faulty Evap Fan Motor Repair or Replace Shorted or Grounded Fan Motor Test Motor Windings Improper Cooling Anticipator Check Resistance of Anticipator Shortag...

Страница 11: ...airflow If cleaning of the outdoor coil becomes necessary hire a qualified servicer Inexperienced people could easily puncture the tubing in the coil Even a small hole in the tubing could eventually c...

Страница 12: ...gh not required to get the protection of the standard warranty registering your product is a relatively short process and entitles you to additional warranty protection except that failure by Californ...

Отзывы: