Important Safety Instructions

The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.  It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying these
symbols.  Failure to heed safety information increases the risk
of personal injury, property damage, and/or product damage.

Only personnel that have been trained to install, adjust, service or 
repair (hereinafter, “service”) the equipment specified in this manual 
should service the equipment. The manufacturer will not be 
responsible for any injury or property damage arising from improper 
service or service procedures.  If you service this unit, you assume 
responsibility for any injury or property damage which may result.  In 
addition, in jurisdictions that require one or more licenses to service 
the equipment specified in this manual, only licensed personnel 
should service the equipment.  Improper installation, adjustment, 
servicing or repair of the equipment specified in this manual, or 
attempting to install, adjust, service or repair the equipment specified 
in this manual without proper training may result in product damage, 
property damage, personal injury or death.

Cancer and Reproductive Harm

 -

www.P65Warnings.ca.gov

HIGH VOLTAGE!

 

Failure to do so may cause property damage,

Disconnect ALL power before servicing.
Multiple power sources may be present.

personal injury or death.

Scroll equipped units should never be used to evacuate
the air conditioning system. Vacuums this low can cause
internal electrical arcing resulting in a damaged or failed
compressor.

CAUTION

CONDENSING UNIT

HEAT PUMP
INSTALLATION & SERVICE REFERENCE

©

 2016-2019

 

Goodman Manufacturing Company, L.P.

19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com
P/N:

 

IOG-4002C 

 

Date: October 2019

Shipping Inspection

Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subse-
quent investigation is the responsibility of the carrier.  Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distribu-
tor or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.

Codes & Regulations

This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes and/
or prevailing local codes/regulations is the responsibility of the
installer.  The manufacturer assumes no responsibility for equip-
ment installed in violation of any codes or regulations. Rated
performance is achieved after 20 hours of operation. Rated per-
formance is delivered at the specified airflow. See outdoor unit
specification sheet for split system models or product specifi-
cation sheet for packaged and light commercial models. Speci-
fication sheets can be found at www.goodmanmfg.com for
Goodman

®

 brand products or www.amana-hac.com for Amana

®

brand products. Within either website, please select the resi-
dential or commercial products menu and then select the
submenu for the type of product to be installed, such as air
conditioners or heat pumps, to access a list of product pages
that each contain links to that model’s specification sheet.

The United States Environmental Protection Agency (EPA)
has issued various regulations regarding the introduc-
tion and disposal of refrigerants. Failure to follow these
regulations may harm the environment and can lead to
the imposition of substantial fines. 

Should you have any

questions please contact the local office of the EPA.

If replacing a condensing unit or air handler, the system must
be manufacturer approved and Air Conditioning, Heating and
Refrigeration Institute (AHRI) matched.  

NOTE: 

Installation of

unmatched systems is not allowed.

Outdoor units are approved for operation above 55

°

F in cooling

mode.  Operation below 55

°

F requires the use of an approved

low ambient kit. Note: LAKT01 Low ambient kit cannot be used
with outdoor units containing ECM motors.

Damage to the unit caused by operating the unit in a structure
that is not complete (either as part of new construction or reno-
vation) is not covered under the warranty.

Содержание GSZ16

Страница 1: ...lity of the carrier Verify the model number specifications electrical characteristics and accessories are correct prior to installation The distribu tor or manufacturer will not accept claims from dea...

Страница 2: ...r springs can be installed between the con densing unit legs or frame and the roof mounting assembly to reduce noise vibration NOTE These units require special location consideration in areas of heavy...

Страница 3: ...tance Cond Unit Tons Suct Liq Suct Liq Suct Liq 1 1 2 5 8 1 4 3 4 3 8 3 4 3 8 2 5 8 1 4 3 4 3 8 3 4 3 8 2 1 2 5 8 1 4 3 4 3 8 7 8 3 8 3 3 4 3 8 7 8 3 8 1 1 8 3 8 3 1 2 7 8 3 8 1 1 8 3 8 1 1 8 3 8 4 7...

Страница 4: ...ented lines will cause poor performance or compressor damage Do NOT make final refrigerant line connection until plugs are removed from refrigerant tubing NOTE Before brazing verify indoor piston size...

Страница 5: ...ch located near the unit do not install the switch on the unit Refer to the installa tion instructions supplied with the indoor furnace air handler for specific wiring connections and indoor unit conf...

Страница 6: ...f disabling this function is desired move the jumper from DLY to NORM on the defrost control Adequate refrigerant charge for the matching HSVTC evapora tor coil and 15 feet of lineset is supplied with...

Страница 7: ...Charge Adjustment The outdoor temperature must be 60 F or higher Set the room thermostat to COOL fan switch to AUTO and set the tem perature control well below room temperature Purge gauge lines Conne...

Страница 8: ...URATED SUCTION TEMPERATURE F LIQUID PRESSURE PSIG R 22 R 410A 200 101 70 210 105 73 220 108 76 225 110 78 235 113 80 245 116 83 255 119 85 265 121 88 275 124 90 285 127 92 295 130 95 305 133 97 325 13...

Страница 9: ...nit and refrigerant tubing sizes These adjustments should only be performed by qualified service personnel AdvancedAdjustmentRecommendations SUPERHEATFORMULA SUCTIONLINETEMPERA TURE SATURATEDSUCTIONTE...

Страница 10: ...t with Voltmeter Low Voltage Test Voltage Faulty Evap Fan Motor Repair or Replace Shorted or Grounded Fan Motor Test Motor Windings Improper Cooling Anticipator Check Resistance of Anticipator Shortag...

Страница 11: ...airflow If cleaning of the outdoor coil becomes necessary hire a qualified servicer Inexperienced people could easily puncture the tubing in the coil Even a small hole in the tubing could eventually c...

Страница 12: ...gh not required to get the protection of the standard warranty registering your product is a relatively short process and entitles you to additional warranty protection except that failure by Californ...

Отзывы: