GM9S96-U

 

Dimensions

5

19⅝

34½

¾

19½

¾

 B
 C

23

2⅜

1⅞

2

5

19⅝

23

24⅞

31⅞

A

21⅛

 2⅝

14

23

1⅜

¾

28¾

2⅜

1⅞

2

1⅞

26½

23½

Folded Flanges

22

Unfolded Flanges

D

Unfolded Flanges

E

Folded Flanges

Air

Discharge

Air

Discharge

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

Condensate Drain

Trap Exterior

Connection

(Right or Left Side)

¾

 PVC 

Vent/ Flue Pipe

2" PVC

Alternate 

Vent/ Flue

Location

Right-Side

Drain Trap

Exterior Holes

High-Voltage

Electrical Outlet

Alternate

Gas Supply

Low-Voltage

Electrical Outlet

Standard 

Gas Supply

Location

Center Dimple

For Alternate

Air Intake Pipe

3"

 OD Hole

Air Intake

2" Pipe

Left-Side

Drain Trap

Exterior Holes

High-Voltage

Electrical Outlet

Low-voltage

Electrical Outlet

Air 

Discharge

Air  

 

Return

Model

W

D

H

A

B

C

D

E

GM9S960403BU

17½"

28⅞"

34½"

17½"

16"

13⅞"

12⅛"

13⅝"

GM9S960603BU

17½"

28⅞"

34½"

17½"

16"

13⅞"

12⅛"

13⅝"

GM9S960805CU

 21" 

28⅞"

34½"

 21" 

19½"

17⅞"

16"

17½"

Minimum Clearances to Combustible Materials

Position

Sides

Rear

Front

Bottom

Flue

Top

Upflow

0"

0"

3”

C

0"

1"

Horizontal

6"

0"

3”

C

0"

6”

C = If placed on combustible floor, the floor MUST be wood ONLY.

Downloaded from 

ManualsNet.com

 search engine

Содержание GM9S96

Страница 1: ...a LED Eligible for installation in California s South Coast Air Quality Management District SCAQMD and San Joaquin Valley Air Pollution Control District SJVUAPCD This furnace complies with the 14 ng J...

Страница 2: ...Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4 1600 CFM S Single Stag...

Страница 3: ...is dependent on installation code requirements and must be 2 or 3 diameter PVC Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accordance with...

Страница 4: ...cal Outlet Alternate Gas Supply Low Voltage Electrical Outlet Standard Gas Supply Location Center Dimple For Alternate Air Intake Pipe 3 OD Hole Air Intake 2 Pipe Left Side Drain Trap Exterior Holes H...

Страница 5: ...F01 999 934 877 814 740 681 615 554 F02 1297 1245 1194 1143 1096 1044 991 933 F03 1407 1354 1307 1257 1210 1164 1118 1067 F04 1532 1488 1440 1396 1352 1304 1259 1210 F05 1641 1594 1552 1509 1477 1425...

Страница 6: ...Switch E E 3 Flame Detected When No Flame Should Be Present E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Fault Or Ignitor Relay Fault E E 7 Reversed Line Polarity E E A Grounding Error E 1 0...

Страница 7: ...UT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Outpu...

Страница 8: ...de or bottom 1 20 x 25 bottom or 2 16 x 25 side Note Other size filters of equal or greater dimensions may be used Filters may also be centrally located Model Description GM9S96 0403BU GM9S96 0603BU G...

Отзывы: